Sony MZ-NF810CK Service Manual - Page 21
ChgV H, ChgV L
View all Sony MZ-NF810CK manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
MZ-NF810/NF810CK • Adjustment Method of CHGV_LOW (item number: 755) Remote commander LCD display 755 ChgV L ** **: Adjusted value Note: Remove the rechargeable battery. 1. Connect a digital voltmeter to the BATT+ on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 1.35 ± 0.01V. digital voltmeter MAIN board BATT +(W902) BATT - (GND) 2. Press the X key on the set or the key on the remote commander to write the adjusted value. Adjustment and Connection Location: MAIN board (see page 22) • Adjustment Method of CHGV_HIGH (item number: 756) Remote commander LCD display 756 ChgV H ** **: Adjusted value Note: Remove the rechargeable battery. 1. Connect a digital voltmeter to the BATT + on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 1.80 ± 0.015V. digital voltmeter MAIN board BATT +(W902) BATT - (GND) 2. Press the X key on the set or the key on the remote commander to write the adjusted value. Adjustment and Connection Location: MAIN board (see page 22) • Adjustment Method of CHGI_LOW (Charge Current) (item number: 757) Remote commander LCD display 757 CIL ** **: Adjusted value Note: Remove the rechargeable battery. Connect the resistor (47 ) (0.5%) between terminals of BATT + and BATT -. 1. Connect a digital voltmeter to the BATT + on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 1.41 ± 0.015V. digital voltmeter MAIN board 47 Ω (0.5%) BATT + (W902) BATT - (GND) 2. Press the X key on the set or the key on the remote commander to write the adjusted value. Adjustment and Connection Location: MAIN board (see page 22) • Adjustment Method of CHGI_HIGH (Charge Current) (item number: 758) Remote commander LCD display 758 CIH ** **: Adjusted value Note: Remove the rechargeable battery. Connect the resistor (10 ) (0.5%) between terminals of BATT + and BATT -. 1. Connect a digital voltmeter to the BATT + on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 1.40 ± 0.015V. digital voltmeter MAIN board 10 Ω (0.5%) BATT + (W902) BATT - (GND) 2. Press the X key on the set or the key on the remote commander to write the adjusted value. Adjustment and Connection Location: MAIN board (see page 22) 21