Page 21 highlights

MZ-NF810/NF810CK • Adjustment Method of CHGV_LOW (item number: 755) Remote commander LCD display 755 ChgV L ** **: Adjusted value Note: Remove the rechargeable battery. 1. Connect a digital voltmeter to the BATT+ on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 1.35 ± 0.01V. digital voltmeter MAIN board BATT +(W902) BATT - (GND) 2. Press the X key on the set or the key on the remote commander to write the adjusted value. Adjustment and Connection Location: MAIN board (see page 22) • Adjustment Method of CHGV_HIGH (item number: 756) Remote commander LCD display 756 ChgV H ** **: Adjusted value Note: Remove the rechargeable battery. 1. Connect a digital voltmeter to the BATT + on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 1.80 ± 0.015V. digital voltmeter MAIN board BATT +(W902) BATT - (GND) 2. Press the X key on the set or the key on the remote commander to write the adjusted value. Adjustment and Connection Location: MAIN board (see page 22) • Adjustment Method of CHGI_LOW (Charge Current) (item number: 757) Remote commander LCD display 757 CIL ** **: Adjusted value Note: Remove the rechargeable battery. Connect the resistor (47 ) (0.5%) between terminals of BATT + and BATT -. 1. Connect a digital voltmeter to the BATT + on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 1.41 ± 0.015V. digital voltmeter MAIN board 47 Ω (0.5%) BATT + (W902) BATT - (GND) 2. Press the X key on the set or the key on the remote commander to write the adjusted value. Adjustment and Connection Location: MAIN board (see page 22) • Adjustment Method of CHGI_HIGH (Charge Current) (item number: 758) Remote commander LCD display 758 CIH ** **: Adjusted value Note: Remove the rechargeable battery. Connect the resistor (10 ) (0.5%) between terminals of BATT + and BATT -. 1. Connect a digital voltmeter to the BATT + on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --] key (voltage down) so that the voltage becomes 1.40 ± 0.015V. digital voltmeter MAIN board 10 Ω (0.5%) BATT + (W902) BATT - (GND) 2. Press the X key on the set or the key on the remote commander to write the adjusted value. Adjustment and Connection Location: MAIN board (see page 22) 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

21
MZ-NF810/NF810CK
Adjustment Method of CHGV_LOW
(item number: 755)
Note:
Remove the rechargeable battery.
1.
Connect a digital voltmeter to the BATT+ on the MAIN board,
and adjust
[VOL°+]
key (voltage up) or
[VOL°--]
key (voltage
down) so that the voltage becomes 1.35 ± 0.01V.
2.
Press the
X
key on the set or the
key on the remote
commander to write the adjusted value.
Adjustment and Connection Location:
MAIN board
(see page 22)
Adjustment Method of CHGV_HIGH
(item number: 756)
Note:
Remove the rechargeable battery.
1.
Connect a digital voltmeter to the BATT +
on the MAIN board,
and adjust
[VOL°+]
key (voltage up) or
[VOL°--]
key (voltage
down) so that the voltage becomes 1.80 ± 0.015V.
2.
Press the
X
key on the set or the
key on the remote
commander to write the adjusted value.
Adjustment and Connection Location:
MAIN board
(see page 22)
Adjustment Method of CHGI_LOW (Charge Current)
(item number: 757)
Note:
Remove the rechargeable battery.
Connect the resistor (47 ) (0.5%) between terminals of
BATT + and BATT –.
1.
Connect a digital voltmeter to the BATT +
on the MAIN board,
and adjust
[VOL°+]
key (voltage up) or
[VOL°--]
key (voltage
down) so that the voltage becomes 1.41 ± 0.015V.
2.
Press the
X
key on the set or the
key on the remote
commander to write the adjusted value.
Adjustment and Connection Location:
MAIN board
(see page 22)
Adjustment Method of CHGI_HIGH (Charge Current)
(item number: 758)
Note:
Remove the rechargeable battery.
Connect the resistor (10 ) (0.5%) between terminals of
BATT + and BATT –.
1.
Connect a digital voltmeter to the BATT +
on the MAIN board,
and adjust
[VOL°+]
key (voltage up) or
[VOL°--]
key (voltage
down) so that the voltage becomes 1.40 ± 0.015V.
2.
Press the
X
key on the set or the
key on the remote
commander to write the adjusted value.
Adjustment and Connection Location:
MAIN board
(see page 22)
digital
voltmeter
BATT + (W902)
BATT – (GND)
MAIN board
10
(0.5%)
756
ChgV H **
**
: Adjusted value
Remote commander LCD display
digital
voltmeter
BATT +(W902)
BATT – (GND)
MAIN board
757
CIL **
**
: Adjusted value
Remote commander LCD display
digital
voltmeter
BATT + (W902)
BATT – (GND)
MAIN board
47
(0.5%)
758
CIH **
**
: Adjusted value
Remote commander LCD display
755
ChgV L **
**
: Adjusted value
Remote commander LCD display
digital
voltmeter
BATT +(W902)
BATT – (GND)