Sony VPL DX15 Operating Instructions - Page 65

Messages List, Warning Messages, Caution Messages

Page 65 highlights

Messages List Warning Messages Use the list below to check the meaning of the messages displayed on the screen. Message Meaning and Remedy High temp.! Lamp off in 1 The internal temperature is too high. min. c Turn off the power. c Check to see that nothing is blocking the ventilation holes. Frequency is out of range! Please check Input-A Signal Sel. • This input signal cannot be projected as the frequency is out of the acceptable range of the projector. • The resolution setting of the output signal of the computer is too high. c Input a signal that is within the range of the frequency. You have input an RGB signal from the computer when "Input-A Signal Sel." in the Setup menu is set to "Component." c Set "Input-A Signal Sel." correctly (page 51). Please replace the Lamp. • It is time to replace the lamp. c Replace the lamp (page 58). • If this message appears again after you replace the lamp, the lamp replacement process is not complete. c Perform the operations in step 9 to 12 on page 59. Note To erase a message, press any key on the control panel of the projector or on the remote commander. Please clean the filter. It is time to clean the filter. c Clean the filter (page 60). Note To cancel the message, press any key on the remote commander or the control panel of the main unit. The message is displayed twice, including when the unit is started next time. Projector temperature is high. High Altitude Mode should be "On" if the projector is being used at high altitude. Internal temperature is too high. c When using the projector at an altitude of 1,500 m or higher, set "High Altitude Mode" on the Setup menu to "On" (page 50). c If this message appears on the screen when using the projector at normal altitudes, check to see if anything is blocking the ventilation holes (exhaust) (page 17). Caution Messages Use the list below to check the meaning of the messages displayed on the screen. Message Meaning and Remedy Not applicable! You have pressed the wrong key. c Press the appropriate key. The panel keys are locked! "Panel Key Lock" in the Function menu is set to "On." c All the keys on the control panel of the projector are locked. Operate the projector with the keys on the Remote Commander (page 52). Others Troubleshooting 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

65
Troubleshooting
Others
Warning Messages
Use the list below to check the meaning of the messages displayed on the screen.
Caution Messages
Use the list below to check the meaning of the messages displayed on the screen.
Messages List
Message
Meaning and Remedy
High temp.! Lamp off in 1
min.
The internal temperature is too high.
c
Turn off the power.
c
Check to see that nothing is blocking the ventilation holes.
Frequency is out of range!
This input signal cannot be projected as the frequency is out of the
acceptable range of the projector.
• The resolution setting of the output signal of the computer is too
high.
c
Input a signal that is within the range of the frequency.
Please check Input-A
Signal Sel.
You have input an RGB signal from the computer when “Input-A
Signal Sel.” in the Setup menu is set to “Component.”
c
Set “Input-A Signal Sel.” correctly (page 51).
Please replace the Lamp.
• It is time to replace the lamp.
c
Replace the lamp (page 58).
• If this message appears again after you replace the lamp, the lamp
replacement process is not complete.
c
Perform the operations in step 9 to 12 on page 59.
To erase a message, press any key on the control panel of the
projector or on the remote commander.
Please clean the filter.
It is time to clean the filter.
c
Clean the filter (page 60).
To cancel the message, press any key on the remote commander or
the control panel of the main unit. The message is displayed twice,
including when the unit is started next time.
Projector temperature is
high. High Altitude Mode
should be “On” if the
projector is being used at
high altitude.
Internal temperature is too high.
c
When using the projector at an altitude of 1,500 m or higher, set
“High Altitude Mode” on the Setup menu to “On” (page 50).
c
If this message appears on the screen when using the projector
at normal altitudes, check to see if anything is blocking the
ventilation holes (exhaust) (page 17).
Message
Meaning and Remedy
Not applicable!
You have pressed the wrong key.
c
Press the appropriate key.
The panel keys are locked!
“Panel Key Lock” in the Function menu is set to “On.”
c
All the keys on the control panel of the projector are locked.
Operate the projector with the keys on the Remote Commander
(page 52).
Note
Note