AC Line Filter Thermostats 1. Unplug microwave oven or disconnect power. 1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 2. Remove wire leads. 3. Measure resistance (ohmmeter scale: Rx1): • Normal: 1-3 (coil): Less than 1 ohm; 2-4 (coil): Less than 1 ohm; 3-4 (resistor): 550k-800k ohms • Abnormal: Infinite 3. Measure continuity (ohmmeter scale: Rx1) • Cavity and Magnetron Thermostats- Normal: Continuity; Abnormal: Infinite • Magnetron thermostat opens at 257ºF (125ºC), closes at 185ºF (85ºC) • Cavity thermostat 1 opens at 257ºF (125ºC), closes at -31ºF (-35ºC) • Cavity thermostat 2 opens at 257ºF (125ºC), closes at -31ºF (-35ºC) 3 1 Ground 2 4 L 1 3 BK L G GND Cy R Cx N 2L W Cy 4 5-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

5-5
AC LINE FILTER
1. Unplug microwave oven or disconnect power.
2. Remove wire leads.
3. Measure resistance (ohmmeter scale: Rx1):
• Normal: 1-3 (coil): Less than 1 ohm; 2-4 (coil):
Less than 1 ohm; 3-4 (resistor): 550k-800k
ohms
• Abnormal: Infinite
THERMOSTATS
1. Unplug microwave oven or disconnect power.
2. Remove wire leads.
3. Measure continuity (ohmmeter scale: Rx1)
• Cavity and Magnetron Thermostats—
Normal: Continuity; Abnormal: Infinite
• Magnetron thermostat opens at 257ºF (125ºC),
closes at 185ºF (85ºC)
• Cavity thermostat 1 opens at 257ºF (125ºC),
closes at -31ºF (-35ºC)
• Cavity thermostat 2 opens at 257ºF (125ºC),
closes at -31ºF (-35ºC)