Tray 2 Pick Roller (PL 9.3.67.3), Reassembly Notes
UPC - 095205120011
View all Xerox 3450B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
Reassembly Notes Note When reinstalling the Duplex Guide Plate, make sure the plate is past the flange before you reinstall the springs. Note Be sure that you reinstall the ground wire on the right side of the Duplex Guide Plate. Tray 2 Pick Roller (PL 9.3.67.3) 1. Remove the Tray 2 Paper Pick Assembly (page 8-36). 2. Remove the spring (release from the shaft) on the left side of the pick roller shaft. Caution Be careful not to drop the spring during removal. 3. Remove the bearing on the right end of the pick roller shaft and slide the end of the shaft to the right to disengage the shaft coupling. 4. Pull the center shaft out of the retaining clips. 5. Pull the segmented roller off of the roller core. 6. Slide the new segmented roller on to the roller core and reassemble the Paper Pick Assembly by reversing the previous steps.. Service Parts Disassembly s3450-177 8-41