Yamaha SP2060 SP2060 V1.2 Owners Manual - Page 29

LIBRARY, Displaying the current library, Recalling a library

Page 29 highlights

Foreword Introduction to the SP2060 The Controls and Connectors Panel Operation NOTE • The type names are abbreviated on the SP2060 screen. For example, "24dB/Oct Bessel" is displayed as "24Bessel." • Gc page is displayed if you select "Adjust Gc" for the Type parameter. • Thru No filter is applied. The original characteristics are kept with no attenuation for all frequency ranges. • AdjustGc (Adjustable Gc) Filters with an Adjustable Gc enable you to adjust the gain at the cutoff frequency in the range of -6dB through +6dB. With Gc set to -3dB, the filter is practically a Butterworth filter. And with Gc set to -6dB, the filter is practically a Linkwitz-Riley filter. • Butrwrth (Butterworth) This filter is the most common type of filter. It has a flat pass band and a -3dB gain at the cutoff frequency. • Bessel This filter focuses on the phase characteristics. Although it has a more gradual roll-off than a Butterworth filter, it will pass a square wave without causing ringing. • Linkwitz (Linkwitz-Riley) This filter features the square of the second order. When the output signal from its LPF and HPF are combined, the gain over the entire range is +/-0dB. It has a flat pass band and a -6dB gain at the cutoff frequency. LIBRARY Using libraries facilitates the recall of optimal speaker settings. Up to 60 libraries are available for each component via the DME Designer application. Displaying the current library Pressing the [X-OVER] key repeatedly will select the Current Library display, Library List display, or X-Over display, in this order. The title of the library most recently recalled for each component will be displayed. CURRENT LIBRARY IF2112/95 NOTE Libraries cannot be displayed or recalled for Input channels. If you press an Input channel [SEL] key, a message appears. Recalling a library Follow the steps below to recall a library: 1. Press the [X-OVER] key repeatedly until the Library List display appears on the screen. LIBRARY LIST IF2112/64 2. Press the [SEL] key of an Output channel for a component for which you wish to recall a library. 3. Press the [▲INC]/[▼DEC] keys to select a library. LIBRARY LIST IF2112/64 4. Press the [NEXT/RECALL] key. A confirmation message will appear. LIBRARY RECALL ARE YOU SURE? Panel Operation Network Settings References SP2060 Owner's Manual 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

References
Introduction
to the SP2060
Foreword
The Controls
and Connectors
Network Settings
Panel Operation
Panel Operation
SP2060 Owner’s Manual
29
• Thru
No filter is applied. The original characteristics are kept
with no attenuation for all frequency ranges.
AdjustGc (Adjustable Gc)
Filters with an Adjustable Gc enable you to adjust the gain
at the cutoff frequency in the range of –6dB through
+6dB. With Gc set to –3dB, the filter is practically a But-
terworth filter. And with Gc set to –6dB, the filter is prac-
tically a Linkwitz-Riley filter.
Butrwrth (Butterworth)
This filter is the most common type of filter. It has a flat
pass band and a –3dB gain at the cutoff frequency.
• Bessel
This filter focuses on the phase characteristics. Although it
has a more gradual roll-off than a Butterworth filter, it will
pass a square wave without causing ringing.
Linkwitz (Linkwitz-Riley)
This filter features the square of the second order. When
the output signal from its LPF and HPF are combined, the
gain over the entire range is +/–0dB. It has a flat pass band
and a –6dB gain at the cutoff frequency.
LIBRARY
Using libraries facilitates the recall of optimal speaker set-
tings. Up to 60 libraries are available for each component via
the DME Designer application.
Displaying the current library
Pressing the [X-OVER] key repeatedly will select the Cur-
rent Library display, Library List display, or X-Over display,
in this order.
The title of the library most recently recalled for each com-
ponent will be displayed.
Recalling a library
Follow the steps below to recall a library:
1.
Press the [X-OVER] key repeatedly until the
Library List display appears on the screen.
2.
Press the [SEL] key of an Output channel for
a component for which you wish to recall a
library.
3.
Press the [
INC]/[
DEC] keys to select a
library.
4.
Press the [NEXT/RECALL] key.
A confirmation message will appear.
NOTE
The type names are abbreviated on the SP2060 screen.
For example, “24dB/Oct Bessel” is displayed as “24Bessel.”
Gc page is displayed if you select “Adjust Gc” for the Type
parameter.
NOTE
Libraries cannot be displayed or recalled for Input channels. If
you press an Input channel [SEL] key, a message appears.
CURRENT LIBRARY
IF2112/95
LIBRARY LIST
IF2112/64
LIBRARY LIST
IF2112/64
LIBRARY RECALL
ARE YOU SURE?