Yamaha SP2060 SP2060 V1.2 Owners Manual - Page 30

LIMITER, SCENE, About a scene

Page 30 highlights

Foreword Introduction to the SP2060 The Controls and Connectors Panel Operation 5. To confirm the selection, press the [YES] key. The library is recalled and the unit returns to the Library List display. LIBRARY LIST IF2112/95 To cancel the recall operation, press the [NO] key, instead of the [YES] key. The unit returns to the Library List display. HINT You can use the library data for speaker processor components for DME64N/24N that you have created using DME Designer. LIMITER You can set up the Output channel limiter. The Limiter precludes signal levels higher than a specified threshold to avoid speaker damage from excess output level. Parameter THRESHOLD ATTACK RELEASE Range -54 through 0dB FAST MID SLOW MANUAL (0- 120.0ms) FAST MID SLOW MANUAL 44.1kHz: 6ms-46s, 48kHz: 5ms-42.3s, 88.2kHz: 3ms-23s, 96kHz: 3ms-21.1s Function Sets the threshold value. Sets the attack time. Sets the release time. If you select Fast, Mid, or Slow, the unit automatically sets the optimum value based on the maximum wave length of audio input to the Limiter. NOTE • You can set the attack time only when "Manual" is selected for the Attack parameter. • You can set the release time only when "Manual" is selected for the Release parameter. 1. Press the [LIMITER] key to select the Limiter display. OUT 1 ON/OFF = ON 2. Press the [SEL] key for the target channel. The [SEL] key LED of the selected channel lights up, and the corresponding channel name is displayed. OUT 4 ON/OFF = ON 3. Press the [LIMITER], [BACK] or [NEXT] key to display the On/Off parameter. 4. Press the [▲INC] key to set the On/Off parameter to On to apply the Limiter to the signal. Press the [▼DEC] key to set the On/ Off parameter to Off to cancel the Limiter. 5. Press the [NEXT]/[BACK] keys to select a parameter to edit. OUT 4 THRESHOLD= -54dB 6. Press the [▲INC]/[▼DEC] keys to set the parameter value. SCENE About a scene The SP2060 enables you to store various parameter settings as part of scene, and recall them via the front panel or remotely from DME Designer. You can store the following settings in a scene: • Configuration • Routing • Parameter sets of all components • Scene titles • Scene protection status • INPUT A/B LINK • The title of the library most recently recalled HINT You can protect a scene to forbid overwriting. Panel Operation Network Settings References 30 SP2060 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Panel Operation
SP2060 Owner’s Manual
Foreword
Network Settings
References
Panel Operation
Introduction
to the SP2060
The Controls
and Connectors
30
5.
To confirm the selection, press the [YES] key.
The library is recalled and the unit returns to the Library
List display.
To cancel the recall operation, press the [NO] key, in-
stead of the [YES] key. The unit returns to the Library
List display.
LIMITER
You can set up the Output channel limiter.
The Limiter precludes signal levels higher than a specified
threshold to avoid speaker damage from excess output level.
1.
Press the [LIMITER] key to select the Limiter
display.
2.
Press the [SEL] key for the target channel.
The [SEL] key LED of the selected channel lights up,
and the corresponding channel name is displayed.
3.
Press the [LIMITER], [BACK] or [NEXT] key to
display the On/Off parameter.
4.
Press the [
INC] key to set the On/Off
parameter to On to apply the Limiter to the
signal. Press the [
DEC] key to set the On/
Off parameter to Off to cancel the Limiter.
5.
Press the [NEXT]/[BACK] keys to select a
parameter to edit.
6.
Press the [
INC]/[
DEC] keys to set the
parameter value.
SCENE
About a scene
The SP2060 enables you to store various parameter settings
as part of scene, and recall them via the front panel or re-
motely from DME Designer.
You can store the following settings in a scene:
Configuration
Routing
Parameter sets of all components
Scene titles
Scene protection status
INPUT A/B LINK
The title of the library most recently recalled
HINT
You can use the library data for speaker processor components for
DME64N/24N that you have created using DME Designer.
Parameter
Range
Function
THRESHOLD
–54 through 0dB
Sets the threshold
value.
ATTACK
FAST
MID
SLOW
MANUAL (0–
120.0ms)
Sets the attack time.
RELEASE
FAST
MID
SLOW
MANUAL
44.1kHz: 6ms–46s,
48kHz: 5ms–42.3s,
88.2kHz: 3ms–23s,
96kHz: 3ms–21.1s
Sets the release time.
If you select Fast,
Mid, or Slow, the unit
automatically sets the
optimum value based
on the maximum
wave length of audio
input to the Limiter.
NOTE
You can set the attack time only when “Manual” is selected for
the Attack parameter.
You can set the release time only when “Manual” is selected for
the Release parameter.
LIBRARY LIST
IF2112/95
HINT
You can protect a scene to forbid overwriting.