Troubleshooting a Serial Management Connection 39 Troubleshooting a Serial Management Connection If a command prompt does not appear when attempting to initiate a serial management connection, do the following: 1 Verify that the WX switch is powered on. 2 Verify that the serial cable is fully inserted in the PC and WX switch ports. 3 Verify that the correct modem settings are configured in the terminal emulation application: 9600 bps 8 bits 1 stop No parity Hardware flow control disabled 4 Verify that you opened the connection on the PC port connected to the WX switch. For example, if you inserted the cable in PC port COM1, make sure you open the connection on COM1 instead of COM2 or another port. If none of the previous steps results in a management connection, use another serial cable. Connecting to the Network Use the following procedures to connect a WX switch to MAP access points or other 10/100 Ethernet devices and to gigabit Ethernet devices. Connecting to a MAP or Other 10/100 Ethernet Device The 10/100 Ethernet ports are configured as wired network ports by default. You must change the port type for locally connected MAP access points, and for wired end stations that use AAA through the WX switch to access the network.