Expand Serial Command Specification Page 23 of 46 8.6.5. CF_INPUT3 Command Command "CF_INPUT3_%1" [CR] "VIDEO Select Composite Video Input %1 "S-VIDEO" ------- Select S-Video Input "YPBPR Select Y/Pb/Pr Input Details Select Input-3 and specified source by %1 at the same time. (Only valid when it is in the usual Power On state) Acceptable Response "000" [CR] Unacceptable "%%%" [CR] 8.6.6. CF_INPUT4 Command Command "CF_INPU_%1" [CR] %1 "NETWORK Select DVI Input Details Select Input-4 and specified source by %1 at the same time. (Only valid when it is in the usual Power On state) Note) When Network Manager is not installed, the Command is invalid and response is Error Code, "103". Acceptable Response "000" [CR] Unacceptable "%%%" [CR] 8.6.7. CF_SYSTEM Command Command "CF_SYSTEM_%1" [CR] Input is PC "MODE1 Select Mode 1 "MODE2 Select Mode 2 "MODE3 Select Mode 3 "MODE4 Select Mode 4 "MODE5 Select Mode 5 "AUTO Select system "Auto" "NTSC" --------- Select NTSC "NTSC443" ----- Select NTSC4.43 %1 "PAL Select PAL "SECAM" ------- Select SECAM "PAL-M" -------- Select PAL-M Input is " P A L - N Select PAL-N Video "1080I Select 1080i "1035I Select 1035i " 7 2 0 P Select 720p " 5 7 5 P Select 575p " 4 8 0 P Select 480p "575I Select 575i "480I Select 480i Details Select current selected Input system. (Only valid when it is in the usual Power On state) When Input does not meet the requirement for specified %1, the response will be "101" and the Command does not execute. Note1) "NTSC" / "NTSC4.43" / "PAL" / "SECAM" / "PAL-M" / "PAL-N" is available only when Input is Video or S-Video. Note2) "1080I" / "1035I" / "720p" / "575P" / "480P" / "575I" / "480I" is available only when Input is Y, Pb/Cb, Pr/Cr. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR]

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

Expand Serial Command Specification
Page 23 of 46
8.6.5. CF_INPUT3 Command
Command
“CF_INPUT3_%1” [CR]
%1
“VIDEO” ------------- Select Composite Video Input
“S-VIDEO” ------- Select S-Video Input
“YPBPR” ------------ Select Y/Pb/Pr Input
Details
Select Input-3 and specified source by %1 at the same time. (Only valid when it
is in the usual Power On state)
Acceptable
“000” [CR]
Response
Unacceptable
“%%%” [CR]
8.6.6. CF_INPUT4 Command
Command
“CF_INPU_%1” [CR]
%1
“NETWORK” ---------- Select DVI Input
Details
Select Input-4 and specified source by %1 at the same time. (Only valid when it
is in the usual Power On state)
Note) When Network Manager is not installed, the Command is invalid and
response is Error Code, “103”.
Acceptable
“000” [CR]
Response
Unacceptable
“%%%” [CR]
8.6.7. CF_SYSTEM Command
Command
“CF_SYSTEM_%1” [CR]
Input is PC
“MODE1” ----------- Select Mode 1
“MODE2” ----------- Select Mode 2
“MODE3” ----------- Select Mode 3
“MODE4” ----------- Select Mode 4
“MODE5” ----------- Select Mode 5
%1
Input is
Video
“AUTO” ------------- Select system “Auto”
“NTSC” --------- Select NTSC
“NTSC443” ----- Select NTSC4.43
“PAL” ---------------- Select PAL
“SECAM” ------- Select SECAM
“PAL-M” -------- Select PAL-M
“PAL-N” ------- Select PAL-N
“1080I” ---------- Select 1080i
“1035I” ---------- Select 1035i
“720P” --------- Select 720p
“575P” --------- Select 575p
“480P” --------- Select 480p
“575I” ----------- Select 575i
“480I” ----------- Select 480i
Details
Select current selected Input system. (Only valid when it is in the usual Power
On state)
When Input does not meet the requirement for specified %1, the response will
be “101” and the Command does not execute.
Note1) “NTSC” / “NTSC4.43” / “PAL” / “SECAM” / “PAL-M” / “PAL-N” is
available only when Input is Video or S-Video.
Note2) “1080I” / “1035I” / “720p” / “575P” / “480P” / “575I” / “480I” is available
only when Input is Y, Pb/Cb, Pr/Cr.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]