Canon LV-7565 Serial Functional Specification - Page 36
CR_APCTRL Command, 4.16. CR_TURBO Command, 5. PC Series Status Read Command, 5.1. CR_FSYNC
View all Canon LV-7565 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Expand Serial Command Specification Page 35 of 46 9.4.15. CR_APCTRL Command Command "CR_APCTRL" [CR] Details Read Auto Picture Control setting status Acceptable "000_%1" [CR] Response "L1" --------Auto Picture Control in operation with Level1 %1 "L2" --------Auto Picture Control in operation with Level2 " O F F " - - - - -Auto Picture Control is Off Unacceptable "?" [CR] 9.4.16. CR_TURBO Command Command "CR_TURBO" [CR] Details Read Bright SW setting status Acceptable "000_%1" [CR] Response %1 "ON" --------Bright SW On "OFF" -------Bright SW Off Unacceptable "000_%1" [CR] 9.5. PC Series Status Read Command 9.5.1. CR_FSYNC Command Command "CR_FSYNC" [CR] Details Read Fine Sync value Acceptable "000_%1" [CR] Response %1 Unacceptable "0000" ~ "0031" "Error Code" [CR] --- Invalid "?" [CR When receives unclear Command 9.5.2. CR_TDOTS Command Command "CR_TDOTS" [CR] Details Read Total Dots value Acceptable "000_%1" [CR] Response %1 "nnnn" ~ "9999" (nnnn = Display Dots + Horizontal Position) Unacceptable "Error Code" [CR] --- Invalid "?" [CR When receives unclear Command 9.5.3. CR_CLAMP Command Command "CR_CLAMP" [CR] Details Read Clamp value Acceptable "000_%1" [CR] Response %1 Unacceptable "0000" ~ "0127" "Error Code" [CR] --- Invalid "?" [CR When receives unclear Command