Canon LV-7565 Serial Functional Specification - Page 46
Other Status Read Command, 12.1. CR_SIGNAL Command, 12.2. CR_VMUTE Command, 12.3. CR_FREEZE
View all Canon LV-7565 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
Expand Serial Command Specification Page 45 of 46 9.12. Other Status Read Command 9.12.1. CR_SIGNAL Command Command "CR_SIGNAL" [CR] Details Read information if there is signal or not Acceptable "000_%1" [CR] Response %1 "ON" -------- There is signal "OFF" ------- No signal Unacceptable "?" [CR] 9.12.2. CR_VMUTE Command Command "CR_VMUTE" [CR] Details Read No Show setting status Acceptable "000_%1" [CR] Response %1 "ON Selected No Show "OFF" --------- Canceled No Show Unacceptable "?" [CR] 9.12.3. CR_FREEZE Command Command "CR_FREEZE" [CR] Details Read Freeze setting status Acceptable "000_%1" [CR] Response %1 "ON" --------- Selected Freeze "OFF" -------- Canceled Freeze Unacceptable "?" [CR] 9.12.4. CR_PTIMER Command Command "CR_PTIMER" [CR] Details Read Presentation Timer status Acceptable "000_%1" [CR] Response "ON Presentation timer is active %1 "STOP" ------- Presentation timer is pause "OFF" --------- Presentation timer is inactive Unacceptable "?" [CR] 9.12.5. CR_INFPFAIL Command Command "CR_INFPFAIL" [CR] Details Read the power failure status. Data is shown in 32bits HEX Normal = All Hi (FF) Abnormal = All Lo (00) Acceptable "000_%1" [CR] Response "********" %1 Show 32bits hexadecimal numeral in 8 figures : "FFFFFFFF" = All are normal Unacceptable "?" [CR]