CR_VPOS Command, 8.7. CR_HSCALE Command, 8.8. CR_HPOS Command, 9. Lamp Series Status Read

Page 42 highlights

Expand Serial Command Specification 9.8.6. CR_VPOS Command Command "CR_VPOS" [CR] Details Read V-Position setting status Acceptable "000_%1" [CR] Response %1 "-64" ~ "064" Unacceptable "?" [CR] 9.8.7. CR_HSCALE Command Command "CR_HSCALE" [CR] Details Read H-Scale setting status Acceptable "000_%1" [CR] Response %1 "-32" ~ "032" Unacceptable "?" [CR] 9.8.8. CR_HPOS Command Command "CR_HPOS" [CR] Details Read H-Position setting status Acceptable "000_%1" [CR] Response %1 "-64" ~ "064" Unacceptable "?" [CR] Page 41 of 46 9.9. Lamp Series Status Read Command 9.9.1. CR_LAMPREPL Command Command "CR_LAMPREPL" [CR] Details Read Lamp replacement time information Acceptable "000_%1" [CR] Response %1 "1Y" ------- Over the lamp replacement time "1N" ------ Haven not reached the lamp replacement time Unacceptable "?" [CR] 9.9.2. CR_LAMPMODE Command Command "CR_LAMPMODE" [CR] Details Read Lamp mode setting status Acceptable "000_%1" [CR] Response "NORMAL" -------- Normal Lamp mode %1 "ECO Silent Lamp mode "AUTO Auto Lamp mode Unacceptable "?" [CR]

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

Expand Serial Command Specification
Page 41 of 46
9.8.6. CR_VPOS Command
Command
“CR_VPOS” [CR]
Details
Read V-Position setting status
Acceptable
“000_%1” [CR]
%1
“-64” ~ “064”
Response
Unacceptable
“?” [CR]
9.8.7. CR_HSCALE Command
Command
“CR_HSCALE” [CR]
Details
Read H-Scale setting status
Acceptable
“000_%1” [CR]
%1
“-32” ~ “032”
Response
Unacceptable
“?” [CR]
9.8.8. CR_HPOS Command
Command
“CR_HPOS” [CR]
Details
Read H-Position setting status
Acceptable
“000_%1” [CR]
%1
“-64” ~ “064”
Response
Unacceptable
“?” [CR]
9.9. Lamp Series Status Read Command
9.9.1. CR_LAMPREPL Command
Command
“CR_LAMPREPL” [CR]
Details
Read Lamp replacement time information
Acceptable
“000_%1” [CR]
%1
“1Y” ------- Over the lamp replacement time
“1N” ------ Haven not reached the lamp replacement time
Response
Unacceptable
“?” [CR]
9.9.2. CR_LAMPMODE Command
Command
“CR_LAMPMODE” [CR]
Details
Read Lamp mode setting status
Acceptable
“000_%1” [CR]
%1
“NORMAL” -------- Normal Lamp mode
“ECO” --------------- Silent Lamp mode
“AUTO” ------------- Auto Lamp mode
Response
Unacceptable
“?” [CR]