Compaq Armada m700 Compaq Armada M700 Series of Personal Computers Reference G - Page 167

Solving Infrared Problems, the Device Manager. If

Page 167 highlights

Problem Cannot communicate with another computer. Solving Infrared Problems Possible Cause Solution The appropriate software is not running on both computers. Install the appropriate software on the second device, start the second device, and start the program on both computers. The other computer Communication between does not have an IrDA- infrared devices must use compliant infrared port. the same Your Compaq computer communications protocol. uses the IrDA Check the manufacturer's communications protocol. instructions for connecting with infrared devices or try connecting with a device you know to be IrDA-compliant. The pathway between the Remove the obstruction, infrared ports is align the infrared ports to obstructed, one port is within 30 degrees, and more than 30 degrees position computers within (plus or minus 15 1.5 feet (about 0.5 meter) degrees off the center of each other. line) from the other, or the ports are more than one meter apart. There is an interrupt request (IRQ) conflict. Check for IRQ conflicts in the Device Manager. If two devices have the same IRQ address, reassign one of the devices. There is a baud rate conflict. Select the same baud rate for both computers. There is a conflict with the # bits. Select the same # bits setting for both computers. There is a stop byte conflict. Select the same stop byte for both computers. There is a parity conflict. Select the same parity setting for both computers. Continued 16-10 Troubleshooting

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218

16-10
Troubleshooting
Solving Infrared Problems
Problem
Possible Cause
Solution
Cannot
communicate
with another
computer.
The appropriate software
is not running on both
computers.
Install the appropriate
software on the second
device, start the second
device, and start the
program on both
computers.
The other computer
does not have an IrDA-
compliant infrared port.
Your Compaq computer
uses the IrDA
communications protocol.
Communication between
infrared devices must use
the same
communications protocol.
Check the manufacturer’s
instructions for
connecting with infrared
devices or try connecting
with a device you know to
be IrDA-compliant.
The pathway between the
infrared ports is
obstructed, one port is
more than 30 degrees
(plus or minus 15
degrees off the center
line) from the other, or
the ports are more than
one meter apart.
Remove the obstruction,
align the infrared ports to
within 30 degrees, and
position computers within
1.5 feet (about 0.5 meter)
of each other.
There is an interrupt
request (IRQ) conflict.
Check for IRQ conflicts in
the Device Manager. If
two devices have the
same IRQ address,
reassign one of the
devices.
There is a baud rate
conflict.
Select the same baud
rate for both computers.
There is a conflict with
the # bits.
Select the same # bits
setting for both
computers.
There is a stop byte
conflict.
Select the same stop byte
for both computers.
There is a parity conflict.
Select the same parity
setting for both
computers.
Continued