Compaq ProLiant 5000 ProLiant Server Troubleshooting Guide - Page 119
Event Message, Event Type, Action, PCI Bus Error, Automatic Server Recovery-2 ASR-2, Power Subsystem
View all Compaq ProLiant 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 119 highlights
Diagnostic Tools Table 4-1: Event Messages continued Event Message Event Type PCI Bus Error PCI Bus Error (Slot X, Bus Y, Device Z, Function x) Expansion bus error Automatic Server Recovery-2 (ASR-2) ASR Lockup Detected: System lockup Cause Power Subsystem System Power Supply Failure (Power Supply X) System Power Supplies Not Redundant Real-Time Clock Battery Failing A CPU Power Module (System Board, Socket X) A CPU Power Module (Slot X, Socket Y) System AC Power Problem (Power Supply X) Power supply failure Power supply not redundant System configuration battery low Power module failure AC voltage problem Action Replace the PCI board. Examine the Integrated Management Log (IML) to determine the cause of the lockup, and then refer to Chapter 5, "Error Recovery," for information on problem resolution. Replace the power supply. Add a power supply or replace the failed power supply. Replace the system configuration battery. Replace the power module. Correct problem with AC power supplied to system. continued 4-16 HP Servers Troubleshooting Guide