Compaq ProLiant 5000 ProLiant Server Troubleshooting Guide - Page 237
Array Option ROM is, Smart Array Controllers using
View all Compaq ProLiant 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 237 highlights
POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1767- Slot x Drive Array Option ROM is not programmed correctly. None Controller Option ROM problem. 1768-Slot X Drive Array - Resuming logical drive expansion process None 1769-Slot X Drive Array - Drive(s) disabled due to failure during capacity expansion. Select F1 to continue with logical drives disabled. Select F2 to accept data loss and to re-enable logical drives. None Power was lost while a logical expansion operation was performed. Capacity expansion failed due to one of the following problems: • Array accelerator removed or failed; expansion progress data lost • Expansion progress data could not be read from array accelerator • Expansion aborted due to unrecoverable drive errors • Expansion aborted due to array accelerator errors Action Upgrade firmware on all Smart Array Controllers using Options ROMPaq. Download it from on the following website: www.compaq.com/support No action required. This message is displayed whenever a controller reset or power cycle occurs while array expansion is in progress. Data lost while the array was expanded; therefore, the drives have been temporarily disabled. 1. Press the F2 key to accept the data loss and re-enable the logical drives. 2. Restore data from backup. 3. If caused by bad drive or array accelerator failure, replace drive or array accelerator, as appropriate. continued HP Servers Troubleshooting Guide C-57