Compaq ProLiant 5000 ProLiant Server Troubleshooting Guide - Page 190
Pressing F1 will, EISA Expansion
View all Compaq ProLiant 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 190 highlights
POST Error Messages Table C-3: 100 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 163-Time & Date Not Set 2 short Invalid time or date in configuration memory. The system time is invalid. This may be a result of a loss in battery power. Set the correct time and date using your operating system. If this message persists, you may need to replace the onboard battery. 164-Memory Size Error 2 short Configuration memory incorrect. 164-Memory Size Error 2 short Configuration memory incorrect. The system memory size is different from the last startup. The most common reason is the addition or removal of memory to the system board. Pressing F1 will record the configuration. If this message persists verify that the memory modules are installed correctly. 170-EISA Expansion Device Not Responding None Device not detected. Action Run the server setup utility and correct. Run the server setup utility and correct. Run the server setup utility and correct. Run the server setup utility and correct. continued C-10 HP Servers Troubleshooting Guide