Non-Numeric POST Error Messages or Beeps Only, Table C-2
View all Compaq ProLiant 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 182 highlights
POST Error Messages WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in your server-specific user documentation before removing, replacing, reseating, or modifying system components. Non-Numeric POST Error Messages or Beeps Only Table C-2: Non-Numeric Error Messages or Beeps Only Error Code A Correctable Memory Error occurred prior to this power-up A Critical Error occurred prior to this power-up A processor thermal event occurred prior to this power up, Processor X Audible Beeps None None None Beeps only 2 long, 2 short Probable Source of Problem A memory module has experienced an error which, while recoverable, has generated a predictive failure warning. A catastrophic system error, which caused the server to crash, has been logged. Processor X (1 or 2) has reached an excessive temperature and has stopped operation. The power has cycled because the temperature is too hot. The processor fan is not installed, or is not spinning. Action Run Diagnostics to identify and replace the appropriate memory module. Run Diagnostics. Replace failed assembly as indicated. Check the following information: • The processor and heatsink assembly is properly installed. • Ambient temperature is within an acceptable range. Check fans. continued C-2 HP Servers Troubleshooting Guide