Compaq ProLiant 5000 ProLiant Server Troubleshooting Guide - Page 129
Table 5-1, Automatic Server Recovery-2 ASR-2 Features, Features, Definition
View all Compaq ProLiant 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Error Recovery Table 5-1: Automatic Server Recovery-2 (ASR-2) Features Features Software error recovery Software error recovery time-out Standby recovery server option Standby recovery server port Standby recovery time-out Software error recovery boot option Thermal shutdown UPS shutdown UPS shutdown threshold Definition When enabled, ASR-2 is activated if the operating system stops responding, resulting in a lockup. This feature determines how long the server waits before enabling ASR-2 after an operating system lockup. When enabled, ASR-2 activation initiates a switch to a designated standby recovery server. This port is used to communicate with the recovery server. This feature determines how long the server waits to initiate a switch to a designated standby recovery server after ASR-2 activation. This option allows the server to restart, either initiating the operating system or Diagnostics. When enabled, this feature shuts down the server if a critical thermal error occurs. When enabled, this feature allows the server to perform a shutdown if an uninterruptible power supply (UPS) is activated. This feature determines how long the server waits to shut down after the UPS is activated. If desired, this setting can provide enough time for an administrator to perform any necessary operations or to properly shut down the server. 5-8 HP Servers Troubleshooting Guide