Compaq ProLiant 5000 ProLiant Server Troubleshooting Guide - Page 202
XC-22
View all Compaq ProLiant 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 202 highlights
POST Error Messages Table C-4: 200 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 216-Voltage Regulator Module for Processor X no longer redundant. None Indicated PPM has lost redundancy. 217-Unsupported Processor Detected None System does not recognize processor as supported. 218-Cache Accelerators Not Installed. System Halted 219-Tag Update Rules SRAM Failure. System Halted 219-Snoop Rules SRAM Failure. System Halted None None None Cache accelerators not installed or improperly installed. Catastrophic chipset failure occurred. Catastrophic chipset failure occurred. Action Run Diagnostics. Replace failed assembly as indicated. 1. Check the processor bus speed and processor bus-to-core ratio jumper settings. Refer to the server-specific setup and installation guide for more information. 2. Be sure that all processors in the system have the same core speeds and cache sizes. 3. Be sure that all processors are no more than one stepping apart. ROM should be able to detect this and provide the stepping information. 4. Replace specified processor. Check cache accelerator installation. Replace failed assembly as indicated. Replace failed assembly as indicated. continued C-22 HP Servers Troubleshooting Guide