POST Error Messages Table C-9: 800 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 806-CMOS has been reset Please power off and restore the clear CMOS switch (SW2.2) None The system switch SW2.2 has been turned on and the system configuration data has been cleared from CMOS. This switch must be returned to the default off position for normal operation and to save configuration setup data. The system must be reconfigured. Action 1. Remove power from the system. 2. Locate the system switch SW2.2. Check your serverspecific user documentation for the location of this switch. 3. Return system switch SW2.2 to the off position. 4. Restart the system. 5. Press the F9 key to run the server setup utility and configure the system. 6. Select the primary operating system. 7. Set the date and time. 8. Complete additional configuration as needed. continued HP Servers Troubleshooting Guide C-33