Compaq ProLiant 5000 ProLiant Server Troubleshooting Guide - Page 272
POST message., Repeat these steps
View all Compaq ProLiant 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 272 highlights
ADU Error Messages Table D-1: Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action System board is unable to identify which slots the controllers are in Slot indicator on system board is not working correctly. Firmware recognizes both controllers as being installed in the same slot. 1. Be sure that both controllers are fully seated in their slots. If the problem persists, this might indicate a controller problem or a system board problem. 2. Remove one of the controllers in the configuration and see if the remaining controller generates a POST message. 3. Move the remaining controller to the other slot to see if it still generates a POST message. 4. Repeat these steps with the other controller. If both controllers give POST messages in one slot but not the other, it is a system board problem. If one of the controllers gives POST messages and the other controller does not, replace the controller that is giving the POST messages. Contact an authorized service provider for any warranty replacements. continued D-22 HP Servers Troubleshooting Guide