Dell PowerEdge M420 Dell PowerEdge M420 Systems Owner's Manual - Page 90

The QuickPath Interconnect QPI width degraded., scheduled service time.

Page 90 highlights

Error Code Message Information PCI3006 Message Failed to get Link Tuning or FlexAddress data from iDRAC. Details Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress. Action Update BIOS, and BMC/iDRAC firmware. If the issue persists, see Getting Help. PCI3008 Message A non-fatal PCIe error detected on a component at bus devicefunction . Details System performance may be degraded. Action Cycle input power, update component drivers, remove and reinstall the device at the next service window. PCI3010 Message A non-fatal IO error detected on a component at bus devicefunction . Details System performance may be degraded. Action Cycle input power, update component drivers, remove and reinstall the device at the next service window. PCI3012 Message The QuickPath Interconnect (QPI) width degraded. Details System performance may be degraded. The bus is not operating at maximum speed or width. Action Reset the system, if the problem persists reinstall processors. PCI3014 Message A non-fatal PCIe error detected on a component at slot . Details System performance may be degraded. Action Cycle input power, update component drivers, remove and reinstall the device at the next scheduled service time. PDR0001 Message LCD Message Details Action Fault detected on drive . Fault detected on drive . Check drive. The controller detected a failure on the disk and has taken the disk offline. Remove and re-seat the failed disk. If the issue persists, see Getting Help. PDR0002 Message A predictive failure detected on drive . Details The controller received a SMART error from the drive. The drive is operational but needs replacement. Action The drive will need replacement at the next service window. PDR0016 Message Drive is removed. LCD Message Drive is removed. Check drive. 90

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121

Error Code
Message Information
PCI3006
Message
Failed to get Link Tuning or FlexAddress data from iDRAC.
Details
Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress.
Action
Update BIOS, and BMC/iDRAC firmware. If the issue persists, see
Getting Help
.
PCI3008
Message
A non-fatal PCIe error detected on a component at bus <
bus
>device<
device
>function
<
func
>.
Details
System performance may be degraded.
Action
Cycle input power, update component drivers, remove and reinstall the device at the next
service window.
PCI3010
Message
A non-fatal IO error detected on a component at bus <
bus
>device<
device
>function <
func
>.
Details
System performance may be degraded.
Action
Cycle input power, update component drivers, remove and reinstall the device at the next
service window.
PCI3012
Message
The QuickPath Interconnect (QPI) width degraded.
Details
System performance may be degraded. The bus is not operating at maximum speed or
width.
Action
Reset the system, if the problem persists reinstall processors.
PCI3014
Message
A non-fatal PCIe error detected on a component at slot <
number
>.
Details
System performance may be degraded.
Action
Cycle input power, update component drivers,
remove and reinstall the device at the next
scheduled service time.
PDR0001
Message
Fault detected on drive <
number
>.
LCD Message
Fault detected on drive <
number
>. Check drive.
Details
The controller detected a failure on the disk and has taken the disk offline.
Action
Remove and re-seat the failed disk. If the issue persists, see
Getting Help
.
PDR0002
Message
A predictive failure detected on drive <
number
>.
Details
The controller received a SMART error from the drive.
The drive is operational but needs
replacement.
Action
The drive will need replacement at the next service window.
PDR0016
Message
Drive <
number
> is removed.
LCD Message
Drive <
number
> is removed. Check drive.