Dell PowerEdge M420 Dell PowerEdge M420 Systems Owner's Manual - Page 96
>. Re-seat PSU., Check cables and subsystem components in the system for damage.
View all Dell PowerEdge M420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
Error Code Message Information PSU0006 Message Power supply type mismatch. LCD Message Power supply is incorrectly configured. Check PSU. Details Power supplies should be of the same input type and power rating. Action Install matched power supplies and review proper configuration in this manual. PSU0007 Message Power supply is operating at 110 volts, and could cause a circuit breaker fault. Details A power supply that is designed to operate at 220V, but is connected to a 110V power source requires additional current for operation. The additional current may trip circuitbreakers or cause other electrical issues with the input source. Action Check input power source and cabling. Use recommended input power. Review this Manual. If the issue persists, see Getting Help. PSU0008 Message Details Action Power supply voltage rating does not match the system's requirements. The system does not support mixed voltage power supplies. Install a power supply with the correct voltage rating. PSU0016 Message LCD Message Details Action Power supply is absent. PSU is absent. Check PSU. The supply has been removed or has failed. 1. Remove and reinstall the power supply. 2. Check cables and subsystem components in the system for damage. 3. If the issue persists, see Getting Help. PSU0031 PSU1201 PSU1202 Message Cannot communicate with power supply . LCD Message Cannot communicate with PSU . Re-seat PSU. Details The power supply may operate, however power supply monitoring will be degraded. System performance may be degraded. Action Remove and reinstall the power supply. If the issue persists, see Getting Help. Message Power supply redundancy is lost. Details The power supply will try to operate in a degraded state. System Performance and power redundancy may be degraded or lost. Action Check input power. Reinstall the power supply. If the issue persists, see Getting Help. Message Power supply redundancy is degraded. Details The power supply will try to operate in a degraded state. System Performance and power redundancy may be degraded or lost. 96