Dell S4112F EMC S4112–ON Series Installation Guide October 2021 - Page 11

Table 2. S4112-ON Series LED behavior, Table 3. System management Ethernet port LEDs

Page 11 highlights

Table 2. S4112-ON Series LED behavior LED System Status/Health LED Power LED FAN LED PSU LED Locator LED/System Beacon Master LED 7-segment LED Table 3. System management Ethernet port LEDs LED Link LED Activity LED Table 4. SFP+ port LEDs LED Link LED Activity LED Description ● Solid green-Normal Operation ● Flashing green-Booting ● Solid yellow-Critical system error ● Flashing yellow-Noncritical system error, fan failure, or power supply failure ● Off-No power ● Solid green-Normal ● Solid yellow-POST is in process ● Flashing yellow-Power Supply failure or loss of power redundancy ● Off-No power ● Solid green-Fan powered and running at the expected RPM ● Flashing yellow-Fan failed or loss of cooling redundancy ● Off-No power ● Solid green-Normal ● Flashing yellow-PSU failure ● Flashing green-FW update ● Off-Locator function is disabled ● Flashing blue-Locator function is enabled ● Off-system is the stack slave ● Solid green-System is the stack master or a standalone unit ● Off-No power ● Solid green-displays a hex digit representing the stack unit ID Description ● Off-No link ● Solid green-Link operating at a maximum speed, autonegotiated/forced or 1G ● Solid yellow-Link operating at a lower speed, autonegotiated/forced or 10/100M ● Off-No link ● Flashing green-Port activity Description ● Off-No link ● Solid green-Link operating at maximum speed-10G on an SFP+ port ● Solid yellow-Link operating at a lower speed-1G on an SFP+ port ● Off-No link ● Flashing green-Port activity ● Solid blue, 1 second on/off-Port beacon S4112-ON Series switch 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Table 2. S4112–ON Series LED behavior
LED
Description
System Status/Health LED
Solid green—Normal Operation
Flashing green—Booting
Solid yellow—Critical system error
Flashing yellow—Noncritical system error, fan failure, or
power supply failure
Power LED
Off—No power
Solid green—Normal
Solid yellow—POST is in process
Flashing yellow—Power Supply failure or loss of power
redundancy
FAN LED
Off—No power
Solid green—Fan powered and running at the expected
RPM
Flashing yellow—Fan failed or loss of cooling redundancy
PSU LED
Off—No power
Solid green—Normal
Flashing yellow—PSU failure
Flashing green—FW update
Locator LED/System Beacon
Off—Locator function is disabled
Flashing blue—Locator function is enabled
Master LED
Off—system is the stack slave
Solid green—System is the stack master or a standalone
unit
7-segment LED
Off—No power
Solid green—displays a hex digit representing the stack
unit ID
Table 3. System management Ethernet port LEDs
LED
Description
Link LED
Off—No link
Solid green—Link operating at a maximum speed,
autonegotiated/forced or 1G
Solid yellow—Link operating at a lower speed,
autonegotiated/forced or 10/100M
Activity LED
Off—No link
Flashing green—Port activity
Table 4. SFP+ port LEDs
LED
Description
Link LED
Off—No link
Solid green—Link operating at maximum speed—10G on
an SFP+ port
Solid yellow—Link operating at a lower speed—1G on an
SFP+ port
Activity LED
Off—No link
Flashing green—Port activity
Solid blue, 1 second on/off—Port beacon
S4112–ON Series switch
11