EMC CX400 Installation Guide - Page 19
Reference Document, Connectivity Status - used
View all EMC CX400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
AIX Installation Checklists Task With Access Logix Reference Document 13 Switches Zone For a SAN ❑ Zone the switches to provide a path from each HBA port (host initiator) to the appropriate SPs. Switch management documentation ❑ If MirrorView is installed, create any required zones for it. ❑ Checkpoint - Use switch management software to verify the switch connections to the storage system. 14 Server ❑ Execute the following AIX command: Make target SPs emc_cfgmgr.sh available ❑ Checkpoint - Verify that AIX sees LUNZ devices with the following AIX command: lscfg | grep LUNZ If AIX does not see LUNZ devices • Verify that arraycommpath is set to 1 as described in step 12. • Execute the following AIX command: emc_cfgmgr.sh AIX documentation ❑ Restart the Navisphere Host Agent or run the Navisphere Server Utility with the following AIX commands: Host Agent/ etc/rc.agent stop /etc/rc.agent start Server Utility /usr/lpp/HOSTUTIL/naviserverutil CX-Series Server Software for AIX Installation Guide ❑ Checkpoint - Use Navisphere Manager's Connectivity Status dialog box Navisphere Manager to verify that each HBA is registered with the storage system. administrator's guide and online help ❑ List the LUNZ devices with the following AIX command: lscfg | grep LUNZ AIX documentation ❑ Remove each LUNZ device with the following AIX command: rmdev -dl hdiskn where n is the hdisk number for the LUNZ device. ❑ Execute the following AIX command: emc_cfgmg.sh PowerPath Checklist - New AIX Server and New Storage System 1-9