Epson ActionNote 500C User Manual - Page 94

AT Register Summary

Page 94 highlights

MNP Command Summary (continued) Command &Q6 &Y0 &Y1 %A n %C0 %C1 %D0 %D1 -C n -D0 -D1 -D2 -D3 -P0 -P1 Description Normal mode Recall user profile 0 at power up Recall user profile 1 at power up Set the auto-reliable fallback character ( n =0 to 127) Disable data compression Enable NMP5 data compression Hang up without clearing buffer Clear the receive buffer before hanging up Maximum string length ( n =6 to 250, default=32) Set dictionary size to 512 entries and one/two-way mode (BTLZ) Set dictionary size to 1024 entries and one/two-way mode (BTLZ) Set dictionary size to 2048 entries and one/two-way mode (BTLZ) Set dictionary size to 4096 entries and one/two-way mode (BTLZ) Ignore parity for special characters Process special characters only if they have correct parity AT Register Summary Command S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 Description Auto-answer ring number Ring counter Escape code character Carriage return character Linefeed character Backspace character Wait time, dialing Wait time, before carrier Dial pause duration Carrier response Carrier loss disconnect Tone duration and spacing Escape guard time Range 0-255 0-255 0-127 0-127 0-127 0-31,127 2-255 1-255 0-255 1-255 1-255 10-255 0-255 Unit 1 ring 1 ring ASCII ASCII ASCII ASCII 1 sec 1 sec 1 sec 1/10 sec 1/10 sec 1/1000 sec 1/50 sec Default 000 000 043 013 010 008 002 030 002 006 014 095 050 B-8 Fax/Modem

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121

MNP
Command Summary (continued)
Command
Description
&Q6
Normal mode
&Y0
Recall user profile 0 at power up
&Y1
Recall user profile 1 at power up
%A
n
Set the auto-reliable fallback character (
n
=0 to 127)
%C0
Disable data compression
%C1
Enable NMP5 data compression
%D0
Hang up without clearing buffer
%D1
Clear the receive buffer before hanging up
-C
n
Maximum string length (
n
=6 to 250, default=32)
-D0
Set dictionary size to 512 entries and one/two-way mode (BTLZ)
-D1
Set dictionary size to 1024 entries and one/two-way mode (BTLZ)
-D2
Set dictionary size to 2048 entries and one/two-way mode (BTLZ)
-D3
Set dictionary size to 4096 entries and one/two-way mode (BTLZ)
-P0
Ignore parity for special characters
-P1
Process special characters only if they have correct parity
AT
Register Summary
Command
Description
Range
Unit
Default
S0
Auto-answer ring number
0-255
1 ring
000
S1
Ring counter
0-255
1 ring
000
S2
Escape code character
0-127
ASCII
043
S3
Carriage return character
0-127
ASCII
013
S4
Linefeed character
0-127
ASCII
010
S5
Backspace character
0-31,127
ASCII
008
S6
Wait time, dialing
2-255
1 sec
002
S7
Wait time, before carrier
1-255
1 sec
030
S8
Dial pause duration
0-255
1 sec
002
S9
Carrier response
1-255
1/10 sec
006
S10
Carrier loss disconnect
1-255
1/10 sec
014
S11
Tone duration and spacing
10-255
1/1000 sec
095
S12
Escape guard time
0-255
1/50 sec
050
B-8