Esoteric G-02X Owners Manual EN FR SP - Page 15

Display illumination time setting, Dimmer setting, Operation mode setting, Frequency mode setting

Page 15 highlights

English Operation mode setting Display illumination time setting MODE>*** DISP>*** Use this to set the operation mode of the CLOCK OUT connectors. A.GND (Adaptive Zero Ground) The amp is used to drive the negative connector so that it becomes 0 V. NORM This outputs a clock signal with normal output. Frequency mode setting FREQ>*** Set the clock reference frequency to 44.1 kHz or 48 kHz. Use an EXP mode to increase the range of output frequency options that can be used. oo Set the reference frequency according to the playback source. 44.1 kHz Use for playback of CDs, Super Audio CDs and other 44.1kHz sources. 48 kHz Use for playback of DVDs, DATs and other 48kHz sources. (Some DVDs and DATs are recorded at 44.1 kHz. In this case, use the 44.1kHz setting.) oo 100 kHz and 10 MHz can be output regardless of the selected setting. 44 Sets the reference frequency to 44.1 kHz. The frequency can be set to 44.1, 88.2, 100 or 176.4 kHz or 10 or 22.5792 MHz. 48 Sets the reference frequency to 48 kHz. The frequency can be set to 48, 96, 100 or 192 kHz or 10 or 24.576 MHz. 44EXP Sets the reference frequency to 44.1 kHz. The frequency can be set to 44.1, 88.2, 100, 176.4, 352.8 or 705.6 kHz or 1.4112, 2.8224, 5.6448, 10, 11.2896 or 22.5792 MHz. 48EXP Sets the reference frequency to 48 kHz. The frequency can be set to 48, 96, 100, 192, 384 or 768 kHz or 1.536, 3.072, 6.144, 10, 12.288 or 24.576 MHz. You can set the amount of time that the clock frequency is shown on the display to ON, LONG or SHORT. oo We recommend setting this to LONG or SHORT because display brightness irregularities might occur if the same information is shown without change for a long time. ON In this mode, the display always stays lit. Set the brightness of the display with the dimmer setting. LONG When ordinary display continues without any operation being conducted for about 20 seconds, the display will automatically turn off. SHORT When ordinary display continues without any operation being conducted for about three seconds, the display will automatically turn off. Dimmer setting DIMMER>*** When the display illumination time setting (DISP) is ON, you can adjust the brightness of the unit's display and indicators. oo You can also change this setting using the DIMMER button on a remote control that is included with another Esoteric product such as the P-02X, K-01X or K-03X. 3 c 2 (normal brightness) c 1 c 0 (off ) oo When set to "DIMMER>0", the display will not be lit. oo When unlit, pressing a button will cause the display to light for a few seconds. oo When set to a value other than "DIMMER>3", error messages and settings menu items will be shown at normal brightness ("DIMMER>2"). 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

15
English
Display illumination time setting
DISP>***
You can set the amount of time that the clock frequency is shown on
the display to ON, LONG or SHORT.
o
We recommend setting this to LONG or SHORT because display
brightness irregularities might occur if the same information is
shown without change for a long time.
ON
In this mode, the display always stays lit.
Set the brightness of the display with the dimmer setting.
LONG
When ordinary display continues without any operation being
conducted for about 20  seconds, the display will automatically
turn off.
SHORT
When ordinary display continues without any operation being
conducted for about three seconds, the display will automatically
turn off.
Dimmer setting
DIMMER>***
When the display illumination time setting (DISP) is ON, you can
adjust the brightness of the unit’s display and indicators.
o
You can also change this setting using the DIMMER button on
a remote control that is included with another Esoteric product
such as the P-02X, K-01X or K-03X.
3
c
2
c
1
c
0
(normal brightness)
(off )
o
When set to “DIMMER>0”, the display will not be lit.
o
When unlit, pressing a button will cause the display to light for a
few seconds.
o
When set to a value other than “DIMMER>3”, error messages
and settings menu items will be shown at normal brightness
(“DIMMER>2”).
Operation mode setting
MODE>***
Use this to set the operation mode of the CLOCK OUT connectors.
A.GND (Adaptive Zero Ground)
The amp is used to drive the negative connector so that it
becomes 0 V.
NORM
This outputs a clock signal with normal output.
Frequency mode setting
FREQ>***
Set the clock reference frequency to 44.1 kHz or 48 kHz. Use an EXP
mode to increase the range of output frequency options that can be
used.
o
Set the reference frequency according to the playback source.
44.1 kHz
Use for playback of CDs, Super Audio CDs and other 44.1kHz
sources.
48 kHz
Use for playback of DVDs, DATs and other 48kHz sources.
(Some DVDs and DATs are recorded at 44.1 kHz. In this case,
use the 44.1kHz setting.)
o
100  kHz and 10  MHz can be output regardless of the selected
setting.
44
Sets the reference frequency to 44.1 kHz.
The frequency can be set to 44.1, 88.2, 100 or 176.4 kHz or 10 or
22.5792 MHz.
48
Sets the reference frequency to 48 kHz.
The frequency can be set to 48, 96, 100 or 192  kHz or 10 or
24.576 MHz.
44EXP
Sets the reference frequency to 44.1 kHz.
The frequency can be set to 44.1, 88.2, 100, 176.4, 352.8 or
705.6 kHz or 1.4112, 2.8224, 5.6448, 10, 11.2896 or 22.5792 MHz.
48EXP
Sets the reference frequency to 48 kHz.
The frequency can be set to 48, 96, 100, 192, 384 or 768 kHz or 1.536,
3.072, 6.144, 10, 12.288 or 24.576 MHz.