Esoteric G-02X Owners Manual EN FR SP - Page 18
Troubleshooting, Restoring factory default settings, Turn the unit off. - review
View all Esoteric G-02X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Troubleshooting Restoring factory default settings If you experience a problem with this unit, please take a moment to review the following information before requesting service. If this product still does not operate correctly, contact the retailer where you purchased it. The unit does not turn on. ee Check that the power cord is plugged into a working power outlet. ee Check that the power cord is properly connected to this unit. Settings are retained even if the power plug is disconnected. The clock output is not synchronizing another device. Follow these procedures to restore all settings to their factory defaults and clear the unit's memory. ee Confirm that the clock being output is supported by the device connected to this unit. (Select a clock frequency that the connected device can use.) The input and synchronization of clock signals might vary according to the device. Refer to the owner's manual of each device for how to connect and set them. 1 Turn the unit off. If the unit is on, press the POWER button to turn it off and wait for more than 30 seconds. The desired frequency cannot be selected by pressing the A and B buttons. ee Set the reference frequency with the frequency mode setting (FREQ) first, and then use the A and B buttons (page 15). 2 Press the POWER button while holding down the MENU button. oo Release the MENU button when the unit turns on and the display lights. 18