Haier QFD15ESSNWW Installation Instructions - Page 19

Installation Instructions, Exhausting The Dryer Cont.

Page 19 highlights

ENGLISH INSTALLATION INSTRUCTIONS EXHAUSTING THE DRYER (cont.) • DO cut duct as short as possible and install straight into wall. • DO use elbows when turns are necessary. Elbows • DO NOT bend or collapse ducting. Use elbows if turns are necessary. • DO NOT use excessive exhaust length. Cut duct as short as possible. • DO NOT crush duct against the wall. • DO NOT set dryer on duct. EXHAUST LENGTH Using exhaust longer than specified length will: • Increase the drying times and the energy cost. • Reduce the dryer life. • Accumulate lint, creating a potential fire hazard. The correct exhaust installation is YOUR RESPONSIBILITY. Problems due to incorrect installation are not covered by the warranty. The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct, number of turns, the type of exhaust hood (wall cap) and all conditions noted on the chart. • Internal elbows added for side or bottom vent conversions must be included in the total elbow count. • Any elbow greater than 45° should be treated as a 90° elbow; one elbow of 45° or less may be ignored. • Two 45° elbows will be treated like one 90° elbow. • For the side exhaust installations, add one 90° elbow to the chart. • For every additional 90° elbow, reduce the allowable vent system length by 10 feet. • When calculating the total vent system length, you must add all the straight portions and elbows of the system (including the transition duct). EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended Use only for short run installations 4" DIA. 4" DIA. 4" DIA. No. of 90° Elbows 0 1 2 3 4 4" Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 2-1/2" Rigid Metal 60 Feet 45 Feet 35 Feet 25 Feet 15 Feet 49-3000195 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

49-3000195
19
ENGLISH
INSTALLATION INSTRUCTIONS
EXHAUSTING THE DRYER (cont.)
Using exhaust longer than specified length will:
Increase the drying times and the energy cost.
Reduce the dryer life.
Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR
RESPONSIBILITY.
Problems due to incorrect installation are not covered
by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust system
depends upon the type of duct, number of turns, the type
of exhaust hood (wall cap) and all conditions noted on the
chart.
Internal elbows added for side or bottom vent
conversions must be included in the total elbow count.
Any elbow greater than 45° should be treated as a 90°
elbow; one elbow of 45° or less may be ignored.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to
the chart.
For every additional 90° elbow, reduce the allowable vent
system length by 10 feet.
When calculating the total vent system length, you must
add all the straight portions and elbows of the system
(including the transition duct).
EXHAUST LENGTH
EXHAUST
LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
Use only for short run
installations
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
No. of 90° Elbows
Rigid Metal
Rigid Metal
0
90 Feet
60 Feet
1
60 Feet
45 Feet
2
45 Feet
35 Feet
3
35 Feet
25 Feet
4
25 Feet
15 Feet
DO NOT
bend
or collapse
ducting. Use
elbows if turns
are necessary.
DO NOT
use
excessive
exhaust
length. Cut
duct as short
as possible.
DO NOT
crush duct
against
the wall
.
DO NOT
set dryer
on duct
.
DO
cut duct as short
as possible and install
straight into wall.
DO
use elbows when
turns are necessary.
Elbows