Hayward Pro Logic Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation - Page 10

Optional Remote Controls, Optional Base Station, Optional Valve Actuators - system

Page 10 highlights

Optional Remote Controls Hayward offers a variety of wired and wireless remote control options for the Pro Logic. Each model gives you the ability to control your pool's functions from a remote location, away from the Control Center. Wired Remote Controls Up to 3 wired remote controls can be installed. See "Electrical Wiring" (page 19) for instructions on running the cable from the Pro Logic main unit to the remote control. Also refer to the remote's installation instructions for more information. AQL2-Wx-PS-x (x=4,8, or 16) The AQL2-Wx-PS-x is a wall mounted display/keypad which must be mounted indoors or in a weather protected area (rain should never hit the unit). Note that the number of outputs on the remote ("4", "8" or "16") must match the outputs on the Pro Logic main control unit. This remote control is intended to mount on to a standard electrical utility box (same box as a triple light switch, ideal for new construction) or can be mounted directly onto any wall surface. When selecting a location, note that the wire to the Pro Logic main unit must be less than 500' long. AQL-SS-6B-x, AQL-SS-D-x (x=W or B for White or Black) The AQL-SS-6B and AQL-SS-D are double insulated, waterproof devices which are intended for installation at the water's edge. The remote controls come with an attached 150' cable and are typically installed at the tile-line of the spa wall, or in the deck, within arm's reach of a pool/spa occupant. Wireless Remote Controls A single Base Station must be installed on the Pro Logic in order to use any of the Hayward wireless remote controls. There is no limit on the number of wireless remotes that can used. The maximum distance between wireless remotes and the base station on the Pro Logic main control unit is 400 feet (120m) line of sight or 200 feet (60m) through walls, etc. If in doubt about the distance, test operation before installing the remote. All wireless models require the user to run the "Teach Wireless" routine in the Settings Menu. This information can be found in the Pro Logic Operation Manual and the owner's manual of each remote. AQL2-Wx-RF-PS-x (x=4,8, or 16) The AQL2-Wx-RF-PS-x are wall mounted wireless controls designed to be mounted indoors. These remote controls come with a wall mounted power supply. AQL2-Tx-RF-PS-x (x=4,8, or 16) The AQL2-Tx-RF-PS-x are portable battery operated remote controls designed to be used in a weather protected area (rain should never hit the unit). The AQL2-Tx-RF-PS-x comes with a wall mounted power supply for recharging the built-in batteries. AQL2-SS-RF, AQL2-POD The AQL2-SS-RF and AQL2-POD are waterproof portable remote controls that are designed to be used in and around the pool/spa area. These units float and can be left in the pool/spa water for easy access. Optional Base Station Use the AQL2-BASE-RF for all AQL2 wireless remote controls. To install the base station, remove the knockout on the upper left side of the Pro Logic main control unit, insert the base station, and then tighten the nut from the inside. Also refer to the Base Station manual and the diagram on page 20. Optional Valve Actuators For optional actuators supplied with the Pro Logic-note that the internal cams in the actuator may also have to be adjusted depending on the way the actuator is mounted on the valve and the desired valve action. RETURN SUCTION OUT OUT IN IN IN (Common) 7 OUT (Common) position other than "pool only", or for the first 3 minutes after solar turns on (allows air in the solar panels to be purged). Interlock is not available for solar, low speed filter pump, dimmer, group, super chlorinate or pH dispense functions. Aux1 Group The Aux1 Group function allows the user to perform multiple tasks with a single push of the "Aux1" button. When setting up a Group function, refer to page 22 for specific programming information. There are two Group menus; the first menu determines how the group command will be initiated (Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions and their respective control parameters. When activating Group functions, be aware that the most recent Group function that is initiated will override any previous Group function. Aux1 External Input Interlock When Aux1 External Input Interlock is enabled, the Aux1 output will be forced off when the external input is active. This will have precedence over freeze protection. Aux1 External Input Interlock is not available for solar, low speed filter pump, dimmer, group, super chlorinate, or pH dispense functions. Aux1 Freeze Protection This function protects the pool, plumbing, and equipment against freeze damage. If Freeze Protection is enabled and the AIR temperature sensor falls below the selected freeze protection temperature, the Pro Logic will turn on the aux relay to circulate the water. IMPORTANT: this only enables operation of the AUX output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation system. Freeze Protection is not available for low speed filter pump, dimmer, group, super chlorinate or pH dispense functions. Aux1 Pump Speed This is the speed of the filter pump when the Aux1 output is on. The default selection is "Settings Menu". This is the speed of the pump that has been selected in the Settings Menu for normal filter operation. If an alternate speed is desired when the Aux1 output is on, push "+" or "-" and select from "Lowest" to "Highest" in 5% increments. PL-PS-8-V models only: Aux3 - Aux7 only PL-PS-16-V models only: Aux7 - Aux14 only Aux7 Config. + to view/change Aux7 Name Cleaner Aux7 Relay Standard Aux7 Function Group Aux7 Group Timer: None(Manual) Aux7 Group Filter: Unaffected Push to access Virtual Aux options Move to previous/next configuration menu Rotates between all available names Move to next menu item Toggle between Standard (default) and ColorLogic (must be detected) Move to next menu item or previous/next configuration menu Rotates between Super Chlorinate, Group and Manual On/Off Move to next menu item Rotates between Manual On/Off (default),Countdown Timer and Timeclock Move to next configuration menu item Options available depend on the function that is selected Move to previous/next menu item or next configuration menu For more information on the Group function, refer to page 22. If neither Super Chlorinate, ColorLogic or a Group can be assigned to a Virtual Aux button, the following will be displayed: No Virtual Functions Available 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Optional Remote Controls
Hayward offers a variety of wired and wireless remote control options for the Pro Logic.
Each model gives you
the ability to control your pool’s functions from a remote location, away from the Control Center.
Wired Remote Controls
Up to 3 wired remote controls can be installed.
See “Electrical Wiring” (page 19) for instructions on running the
cable from the Pro Logic main unit to the remote control. Also refer to the remote’s installation instructions for more
information.
AQL2-Wx-PS-x (x=4,8, or 16)
The AQL2-Wx-PS-x is a wall mounted display/keypad which must be mounted indoors or in a weather protected
area (rain should never hit the unit). Note that the
number of outputs on the remote (“4”, “8” or “16”) must match
the outputs on the Pro Logic main control unit.
This remote control is intended to mount on to a standard electrical
utility box (same box as a triple light switch, ideal for new construction) or can be mounted directly onto any wall
surface. When selecting a location, note that the wire to the Pro Logic main unit must be less than 500’ long.
AQL-SS-6B-x, AQL-SS-D-x (x=W or B for White or Black)
The AQL-SS-6B and AQL-SS-D are double insulated, waterproof devices which are intended for installation at
the water's edge.
The remote controls come with an attached 150’ cable and are typically installed at the tile-line
of the spa wall, or in the deck, within arm's reach of a pool/spa occupant.
Wireless Remote Controls
A single Base Station must be installed on the Pro Logic in order to use any of the Hayward wireless remote
controls.
There is no limit on the number of wireless remotes that can used. The maximum distance between
wireless remotes and the base station on the Pro Logic main control unit is 400 feet (120m) line of sight or 200 feet
(60m) through walls, etc.
If in doubt about the distance, test operation before installing the remote. All wireless
models require the user to run the “Teach Wireless” routine in the Settings Menu.
This information can be found in
the Pro Logic Operation Manual and the owner’s manual of each remote.
AQL2-Wx-RF-PS-x (x=4,8, or 16)
The AQL2-Wx-RF-PS-x are wall mounted wireless controls designed to be mounted indoors. These remote
controls come with a wall mounted power supply.
AQL2-Tx-RF-PS-x (x=4,8, or 16)
The AQL2-Tx-RF-PS-x are portable battery operated remote controls designed to be used in a weather pro-
tected area (rain should never hit the unit). The AQL2-Tx-RF-PS-x comes with a wall mounted power supply for
recharging the built-in batteries.
AQL2-SS-RF, AQL2-POD
The AQL2-SS-RF and AQL2-POD are waterproof portable remote controls that are designed to be used in and
around the pool/spa area.
These units float and can be left in the pool/spa water for easy access.
Optional Base Station
Use the AQL2-BASE-RF for all AQL2 wireless remote controls.
To install the base station, remove the knockout
on the upper left side of the Pro Logic main control unit, insert the base station, and then tighten the nut from the
inside.
Also refer to the Base Station manual and the diagram on page 20.
Optional Valve Actuators
For optional actuators supplied with the Pro Logic—note that the internal cams in the actuator may also have to be
adjusted depending on the way the actuator is mounted on the valve and the desired valve action.
7
RETURN
SUCTION
OUT
(Common)
IN
(Common)
OUT
IN
OUT
IN
36
position other than “pool only”, or for the first 3 minutes after solar turns on (allows air in the solar
panels to be purged).
Interlock is not available for solar, low speed filter pump, dimmer, group, super
chlorinate or pH dispense functions.
Aux1 Group
The Aux1 Group function allows the user to perform multiple tasks with a single push of the “Aux1”
button. When setting up a Group function, refer to page 22 for specific programming information.
There are two Group menus; the first menu determines how the group command will be initiated
(Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions
and their respective control parameters.
When activating Group functions, be aware that the most recent Group function that is initiated will
override any previous Group function.
Aux1 External Input Interlock
When Aux1 External Input Interlock is enabled, the Aux1 output will be forced off when the external
input is active.
This will have precedence over freeze protection. Aux1 External Input Interlock is not
available for solar, low speed filter pump, dimmer, group, super chlorinate, or pH dispense functions.
Aux1 Freeze Protection
This function protects the pool, plumbing, and equipment against freeze damage.
If Freeze Protection
is enabled and the AIR temperature sensor falls below the selected freeze protection temperature, the
Pro Logic will turn on the aux relay to circulate the water.
IMPORTANT:
this only enables operation
of the AUX output during freeze--see the “Filter Pump Config.” menu to enable freeze protection for
the main circulation system.
Freeze Protection is not available for low speed filter pump, dimmer,
group, super chlorinate or pH dispense functions.
Aux1 Pump Speed
This is the speed of the filter pump when the Aux1 output is on. The default selection is “Settings
Menu”.
This is the speed of the pump that has been selected in the Settings Menu for normal filter
operation. If an alternate speed is desired when the Aux1 output is on, push “+” or “-” and select from
“Lowest” to “Highest” in 5% increments.
PL-PS-8-V models only:
Aux3 - Aux7 only
PL-PS-16-V models only:
Aux7 - Aux14 only
Aux7 Relay
Standard
Toggle between Standard (default) and ColorLogic (must be detected)
Move to next menu item or previous/next configuration menu
Aux7 Config.
+ to view/change
Aux7 Function
Group
Aux7 Group
Filter: Unaffected
Aux7 Group
Timer: None(Manual)
Push to access Virtual Aux options
Rotates between Super Chlorinate,
Group and Manual On/Off
Options available depend on the function that is selected
Rotates between Manual On/Off (default),Countdown Timer and Timeclock
Move to previous/next configuration menu
Move to next menu item
Move to previous/next menu item or next configuration menu
Move to next configuration menu item
Aux7 Name
Cleaner
Rotates between all available names
Move to next menu item
For more information on the Group function, refer to page 22.
If neither Super Chlorinate, ColorLogic or a Group
can be assigned to a Virtual Aux button, the following will be displayed:
No Virtual