Hayward Variable Speed Pump Owners Manual - Page 15

Wall Mounted Digital Control Interface Wiring Optional, Hayward Control Wiring For remote control - will not prime

Page 15 highlights

5.2. Wall Mounted Digital Control Interface Wiring (Optional) Figure 5.2-1 Note: Connection wire must be rated for a minimum of 300V, and may be up to 500 feet in length. Use removable 6-position terminal block connectors for wiring connection to display and motor drive board taking care to note the wire colors and corresponding numbers next to the connectors. Do not connect to the upper input terminals shown as light gray above. 5.3. Hayward Control Wiring (For remote control of pump speed) Note: For software compatible Hayward controls only Figure 5.3-1 The EcoStar pump can communicate with and be controlled by Hayward Pro Logic, E-Command 4, and OnCommand pool controls. Minimum software revision requirements: Pro Logic/Pro Plus 3.00, OnCommand 1.00, ECommand 2.65, ECommand 4 2.80, and Aqua Logic/Aqua Plus 2.65. To determine Hayward control software revision, consult the appropriate Hayward pool control installation manual or visit our website at www.haywardpool.com. Connection wire must be rated for a minimum of 300V, and may be up to 500 feet in length. Use removable 2-position terminal block connector for wiring connection to motor drive board taking care to note the wire colors and corresponding numbers next to the connectors. Do not connect to the upper input terminals shown as light gray above. Once installed, Remote Control Mode must be set to Standalone/Hayward in the pump Configuration Menu (see section 6.6), and COMM Bus Address must be set according to instructions provided in the Hayward pool control installation manual. It is best to leave the max/min allowed speeds in the pump configuration menu set to their factory defaults to prevent conflict with these settings in the Hayward pool control configuration menu. Preset Speeds 1-4 and Quick Clean are disabled when the pump is remotely controlled. Max-speed Prime Period is disabled only when the pump is communicating with a Hayward pool control. Page 15 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS EcoStar Variable Speed Pump IS3401VSP Rev-2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 15 of 36
EcoStar Variable Speed Pump
IS3401VSP
Rev-2
5.2.
Wall Mounted Digital Control Interface Wiring (Optional)
Figure 5.2-1
Note:
Connection wire must be rated for a minimum of 300V, and may be up to 500 feet in length. Use removable
6-position terminal block connectors for wiring connection to display and motor drive board taking care to note the
wire colors and corresponding numbers next to the connectors. Do
not
connect to the upper input terminals shown
as light gray above.
5.3.
Hayward Control Wiring (For remote control of pump speed)
Note:
For software compatible Hayward controls only
Figure 5.3-1
The EcoStar pump can communicate with and be controlled by Hayward Pro Logic, E-Command 4, and OnCommand
pool controls. Minimum software revision requirements:
Pro Logic/Pro Plus 3.00, OnCommand 1.00, ECommand
2.65, ECommand 4 2.80, and Aqua Logic/Aqua Plus 2.65.
To determine Hayward control software revision, consult
the appropriate Hayward pool control installation manual or visit our website at www.haywardpool.com. Connection
wire must be rated for a minimum of 300V, and may be up to 500 feet in length. Use removable 2-position terminal
block connector for wiring connection to motor drive board taking care to note the wire colors and corresponding
numbers next to the connectors. Do
not
connect to the upper input terminals shown as light gray above.
Once installed, Remote Control Mode must be set to Standalone/Hayward in the pump Configuration Menu (see
section 6.6), and COMM Bus Address must be set according to instructions provided in the Hayward pool control
installation manual.
It is best to leave the max/min allowed speeds in the pump configuration menu set to their
factory defaults to prevent conflict with these settings in the Hayward pool control configuration menu. Preset
Speeds 1-4 and Quick Clean are disabled when the pump is remotely controlled.
Max-speed Prime Period is
disabled only when the pump is communicating with a Hayward pool control.