Page 28 highlights
Figure 9.6-1: Removing the Variable Speed Drive Note: Motor leads must be disconnected prior to removing drive, and reconnected when new drive is mounted. Take care to ensure that the motor leads are not pinched between the drive enclosure and the motor during assembly. The drive mounting screws must be tightened to 30 inch-pounds. Page 28 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS EcoStar Variable Speed Pump IS3401VSP Rev-2
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 28 of 36
EcoStar Variable Speed Pump
IS3401VSP
Rev-2
Figure 9.6-1: Removing the Variable Speed Drive
Note:
Motor leads must be disconnected prior to removing drive, and reconnected when new drive is mounted.
Take care to ensure that the motor leads are not pinched between the drive enclosure and the motor during
assembly.
The drive mounting screws must be tightened to 30 inch-pounds.