2. Menu/navigation buttons: The MENU button will scroll through the setup menus when pressed. The < and > arrow buttons are used to move between displays and to select parameters to edit, and the + and - arrow buttons are used to change parameters. 3. Status LEDs: The CHECK SYSTEM LED will illuminate when the pump is experiencing an error condition. For SP3400VSPVR, it will also flash on and off when the system is in QUICK CLEAN mode to indicate that the SVRS feature is inactive (see "Quick Clean" below). The TIMERS ACTIVE LED will illuminate once timers have been programmed to run the pump, even if the pump is not presently running. 4. Stop/Resume: This button is used to stop the pump to allow strainer basket cleaning, etc. When this button is pressed, the pump will remain stopped until the button is pressed a second time to resume normal operation. When the pump is stopped, the red LED beside the button will illuminate to indicate that the pump has been stopped. 5. Quick Clean: QUICK CLEAN is a mode intended for use when the pool will be cleaned with a suction side vacuum. While in Quick Clean mode for SP3400VSPVR, the SVRS feature is disabled for 60 minutes to prevent nuisance tripping during cleaning. Users will be prompted to check and verify that all bathers are out of the pool during this time. The LED beside the button will illuminate when Quick Clean is active, and the CHECK SYSTEM LED will blink indicating that the SVRS feature is disabled. 6.4. Menu Outline 1. Configuration Menu (see section 6.6 for basic product configuration) a. Set Day and Time b. Speed Selection c. MAX Allowed Speed d. MIN Allowed Speed e. Set max-speed Prime Period f. Remote Control Mode g. Set COMM Bus Address h. SVRS Restart i. Low Temp Operation j. Low Temp Speed k. Drive Temp Setting 2. Timer Menu (see section 6.7 to program the 8 speeds with timer functions) a. Rename Timer "X" (where "X" equals 1 through 8) b. Pump Speed for Timer "X" (where "X" equals 1 through 8) c. Start/Stop Time for Timer "X" (where "X" equals 1 through 8) d. Choose Days for Timer "X" (where "X" equals 1 through 8) 3. Preset Speed Setup Menu (see section 6.8 to program the 4 preset speeds) a. Speed "X" Name (where "X" equals 1 through 4) b. Speed "X" Duration (where "X" equals 1 through 4) c. Speed "X" Speed (where "X" equals 1 through 4) 4. Diagnostics Menu (see section 6.9 to view product diagnostic information) a. Drive Serial Number b. Motor Drive/Display Firmware Revisions c. Input Voltage Status d. Motor Current e. Power Usage f. Driver/Heatsink Temperatures g. COMM Bus Status h. Event Log (if applicable) Page 19 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS EcoStar Variable Speed Pump IS3401VSP Rev-2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 19 of 36
EcoStar Variable Speed Pump
IS3401VSP
Rev-2
2.
Menu/navigation buttons:
The MENU button will scroll through the setup menus when pressed.
The < and >
arrow buttons are used to move between displays and to select parameters to edit, and the + and - arrow
buttons are used to change parameters.
3.
Status LEDs:
The CHECK SYSTEM LED will illuminate when the pump is experiencing an error condition.
For
SP3400VSPVR, it will also flash on and off when the system is in QUICK CLEAN mode to indicate that the SVRS
feature is inactive (see “Quick Clean” below).
The TIMERS ACTIVE LED will illuminate once timers have been
programmed to run the pump, even if the pump is not presently running.
4.
Stop/Resume:
This button is used to stop the pump to allow strainer basket cleaning, etc.
When this button is
pressed, the pump will remain stopped until the button is pressed a second time to resume normal operation.
When the pump is stopped, the red LED beside the button will illuminate to indicate that the pump has been
stopped.
5.
Quick Clean:
QUICK CLEAN is a mode intended for use when the pool will be cleaned with a suction side
vacuum.
While in Quick Clean mode for SP3400VSPVR, the SVRS feature is disabled for 60 minutes to prevent
nuisance tripping during cleaning.
Users will be prompted to check and verify that all bathers are out of the pool
during this time.
The LED beside the button will illuminate when Quick Clean is active, and the CHECK SYSTEM
LED will blink indicating that the SVRS feature is disabled.
6.4.
Menu Outline
1.
Configuration Menu
(see section 6.6 for basic product configuration)
a.
Set Day and Time
b.
Speed Selection
c.
MAX Allowed Speed
d.
MIN Allowed Speed
e.
Set max-speed Prime Period
f.
Remote Control Mode
g.
Set COMM Bus Address
h.
SVRS Restart
i.
Low Temp Operation
j.
Low Temp Speed
k.
Drive Temp Setting
2.
Timer Menu
(see section 6.7 to program the 8 speeds with timer functions)
a.
Rename Timer “X” (where “X” equals 1 through 8)
b.
Pump Speed for Timer “X” (where “X” equals 1 through 8)
c.
Start/Stop Time for Timer “X” (where “X” equals 1 through 8)
d.
Choose Days for Timer “X” (where “X” equals 1 through 8)
3.
Preset Speed Setup Menu
(see section 6.8 to program the 4 preset speeds)
a.
Speed “X” Name (where “X” equals 1 through 4)
b.
Speed “X” Duration (where “X” equals 1 through 4)
c.
Speed “X” Speed (where “X” equals 1 through 4)
4.
Diagnostics Menu
(see section 6.9 to view product diagnostic information)
a.
Drive Serial Number
b.
Motor Drive/Display Firmware Revisions
c.
Input Voltage Status
d.
Motor Current
e.
Power Usage
f.
Driver/Heatsink Temperatures
g.
COMM Bus Status
h.