Installing the solid rack top plate
View all HP 10642 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
3. Using a T-30 Torx screwdriver, remove the M6 flathead screw securing each hinge bracket to the rack (1), and then remove all of the hinge brackets from the rack (2). Retain the hinge brackets and screws for reinstallation. 4. Using a T-25 Torx driver, remove the upper and lower rear door lock catches by removing the two screws from each of the upper and lower rear door lock catches. Retain the door lock catches and screws for reinstallation. NOTE: Install the solid rear rack doors after you have installed the AF028A kit. Installing the solid rack top plate 1. Using a T-30 Torx screwdriver, remove the four M-12 bolts at each corner of the perforated top plate of the rack (1). Retain the bolts for future use. Rack Air Duct kit 89
Rack Air Duct kit
89
3.
Using a T-30 Torx screwdriver, remove the M6 flathead screw securing each hinge bracket to the rack
(1), and then remove all of the hinge brackets from the rack (2). Retain the hinge brackets and screws
for reinstallation.
4.
Using a T-25 Torx driver, remove the upper and lower rear door lock catches by removing the two
screws from each of the upper and lower rear door lock catches. Retain the door lock catches and
screws for reinstallation.
NOTE:
Install the solid rear rack doors after you have installed the AF028A kit.
Installing the solid rack top plate
1.
Using a T-30 Torx screwdriver, remove the four M-12 bolts at each corner of the perforated top plate of
the rack (1). Retain the bolts for future use.