Environmental specifications, Electrical specifications, Operating environment, Storage environment
UPC - 882780301092
View all HP 175X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
Height Weight Weight 45 mm (1.8 in) 108 g (3.9 oz) 36 mm (1.4 in) Environmental specifications Temperature Relative humidity Altitude Operating environment 0° C to 55° C (32° F to 131° F) 15% to 95% at 40° C (104° F) 4.6 km (15,000 ft) Acoustic Noise: Not applicable Storage environment -40° C to 70° C (-40° F to 158° F) 15% to 90% at 65° C (149° F) 4.6 km (15,000 ft) Electrical specifications Power requirements Input voltage Nominal output voltage Input current Max. output current Frequency range Power consumption Print server 13 Vdc n/a 140 mA @ 13 V n/a dc 1.8 W Power module See "input rating" for power modules below 13 Vdc 100 mA Depends on particular power module 300 mA 50/60 Hz Depends on particular power module 1.2 W Power modules Countries/Regions Part num. Australia, New Zealand, 0950-3172 Argentina 0950-3358 China 0950-2806 0950-3347 Continental Europe 0950-3170 0950-3349 Input rating 240 Vac 50 Hz 240 Vac 50 Hz 220 Vac 50 Hz 220 Vac 50 Hz 230 Vac 50 Hz 230 Vac 50 Hz Output rating 13 Vdc @ 300 mA 13 Vdc @ 800 mA 13 Vdc @ 300 mA 13 Vdc @ 800 mA 13 Vdc @ 300 mA 13 Vdc @ 800 mA