AC three-phase power cable specifications Configuration 4 wires, L1/L2/L3/PE Wire Strained Cu minimum, 10 mm² or 6 AWG Terminals Lines, ferrule terminals, PE, M8 ring terminal External diameter range 22.0-33.0 mm Configuration 3: 380-415 V line-to-line three-phase configuration with single-phase control Specifications Three-phase line Single-phase control Number of power wires 5 (L1/L2/L3/N/PE) 3 (L/N/PE) Input voltage (line-to-line) 380-415 V 100-240 V Input frequency 50/60 Hz 50/60 Hz Power consumption (typical) 9-11 kW 0.5 kW Maximum load current (per phase) 35 A 10 A Branch circuit breaker specifications Three-phase Two-phase control 4 poles, 40/50 A 2 poles, 15/16/20 A AC Power cable specifications Configuration Wire Terminals External diameter range Three-phase line Single-phase line 5 wires, L1/L2/L3/N/PE 3 wires, L/N/PE Strained Cu minimum, 10 mm² or 8 AWG Strained Cu minimum, 1.5 mm² or 16 AWG Lines, ferrule terminals, PE, M8 ring terminal Lines, ferrule terminals, PE, M4 ring terminal 22.0-33.0 mm 5.0-11.0 mm Configuration 4: 200-240 V line-to-line three-phase configuration with single-phase control Specifications Three-phase line Single-phase control Number of power wires 4 (L1/L2/L3/PE) 3 (L/N/PE) Input voltage (line-to-line) 200-240 V 100-240 V Input frequency 50/60 Hz 50/60 Hz Power consumption (typical) 9-11 kW 0.5 kW Maximum load current (per phase) 56 A 10 A 8 Chapter 2 Site preparation ENWW