HP Latex 3200 Site Preparation Guide - Page 17

Room and spacial requirements

Page 17 highlights

Pneumatic connector The printer comes with an air gun that you must attach to your air supply. In order to connect your air supply to the air gun, you must meet the following requirements: ● 6.35 mm (0.25 in) female connector, BSP or NPT thread ● PTFE tape to secure the connection and prevent air leaks Room and spacial requirements Temperature and humidity The temperature, humidity, and temperature gradient during operation and during storage must be kept within the standard ranges to ensure the correct operation of the printer. Failure to keep these environmental conditions within the standard ranges may cause image quality problems or damage sensitive electronic components. Printer environmental specifications Temperature range Operating for optimal print quality 20 to 25°C (68 to 77°F) Operating for standard printing 15 to 30°C (59 to 86°F) Not operating (in transport or storage), ink in tubes 5 to 55°C (41 to 131°F) Not operating (in transport or storage), no ink in tubes -25 to 55°C (-13 to 131°F) Humidity range 30 to 60% relative humidity Temperature gradient 10°C/h (50°F/h) or less 20 to 70% relative humidity 90% relative humidity at 55°C (131°F) 90% relative humidity at 55°C (131°F) 10°C/h (50°F/h) or less 10°C/h (50°F/h) or less 10°C/h (50°F/h) or less Maximum operating altitude: 3000 m (10000 ft) In addition to controlling the temperature, humidity, and temperature gradient, there are other environmental conditions that must be met during site preparation: ● Do not install the printer where it will be exposed to direct sunlight or a strong light source. ● Do not install the printer in a dusty environment. Remove any accumulated dust before moving the printer into the area. Ventilation Ensure that the room in which the system is installed meets local environmental, health, and safety (EHS) guidelines and regulations. Adequate ventilation needs to be provided to ensure that potential airborne exposure is adequately controlled according to Safety Data Sheets. Consult the Safety Data Sheets available at http://www.hp.com/go/msds/ to identify chemical ingredients of your ink consumables. Airborne materials can be readily identified and quantified by using established indoor air-quality testing protocols. HP performs these assessments during the development phase for all products. HP testing shows that, during printer operation, the concentrations of airborne contaminants measured in the workspace are consistently well below key occupational exposure limits. This observation is based on exposure assessments that model very active productivity at customer facilities. Customers should recognize that actual levels in their facilities are dependent on workspace variables they control such as room size, ventilation performance, and duration of equipment use. HP's assessment concluded, based on the available scientific information, that airborne materials are not expected to present a health hazard as long as you provide a minimum of 10 ACH (air changes per hour) of fresh air ventilation and a minimum room volume of 80 m³. ENWW Room and spacial requirements 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

Pneumatic connector
The printer comes with an air gun that you must attach to your air supply. In order to connect your air supply to
the air gun, you must meet the following requirements:
6.35 mm (0.25 in) female connector, BSP or NPT thread
PTFE tape to secure the connection and prevent air leaks
Room and spacial requirements
Temperature and humidity
The temperature, humidity, and temperature gradient during operation and during storage must be kept within
the standard ranges to ensure the correct operation of the printer. Failure to keep these environmental
conditions within the standard ranges may cause image quality problems or damage sensitive electronic
components.
Printer environmental specifications
Temperature range
Humidity range
Temperature gradient
Operating for optimal print
quality
20 to 25°C (68 to 77°F)
30 to 60% relative humidity
10°C/h (50°F/h) or less
Operating for standard printing
15 to 30°C (59 to 86°F)
20 to 70% relative humidity
10°C/h (50°F/h) or less
Not operating (in transport or
storage), ink in tubes
5 to 55°C (41 to 131°F)
90% relative humidity at 55°C
(131°F)
10°C/h (50°F/h) or less
Not operating (in transport or
storage), no ink in tubes
–25 to 55°C (–13 to 131°F)
90% relative humidity at 55°C
(131°F)
10°C/h (50°F/h) or less
Maximum operating altitude: 3000 m (10000 ft)
In addition to controlling the temperature, humidity, and temperature gradient, there are other environmental
conditions that must be met during site preparation:
Do not install the printer where it will be exposed to direct sunlight or a strong light source.
Do not install the printer in a dusty environment. Remove any accumulated dust before moving the printer
into the area.
Ventilation
Ensure that the room in which the system is installed meets local environmental, health, and safety (EHS)
guidelines and regulations.
Adequate ventilation needs to be provided to ensure that potential airborne exposure is adequately controlled
according to Safety Data Sheets. Consult the Safety Data Sheets available at
go/msds/
to
identify chemical ingredients of your ink consumables. Airborne materials can be readily identified and quantified
by using established indoor air-quality testing protocols. HP performs these assessments during the
development phase for all products. HP testing shows that, during printer operation, the concentrations of
airborne contaminants measured in the workspace are consistently well below key occupational exposure limits.
This observation is based on exposure assessments that model very active productivity at customer facilities.
Customers should recognize that actual levels in their facilities are dependent on workspace variables they
control such as room size, ventilation performance, and duration of equipment use.
HP’s assessment concluded, based on the available scientific information, that airborne materials are not
expected to present a health hazard as long as you provide a minimum of 10 ACH (air changes per hour) of fresh
air ventilation and a minimum room volume of 80 m³.
ENWW
Room and spacial requirements
13