Specifications (continued) Input voltage (line-to-line) Input frequency Power consumption (typical) Maximum load current (per phase) Two-phase line 240 V 50/60 Hz 9-11 kW 72 A Single-phase control 100-240 V 50/60 Hz 0.5 kW 10 A Branch circuit breaker specifications Two-phase line Two-phase control 2 poles, 90 A 2 poles, 15/16/20 A AC power cable specifications Configuration Wire Terminals External diameter range Two-phase line Single-phase control 3 wires, L1/L2/ PE 3 wires, L/N/PE Strained Cu minimum, 4 AWG Strained Cu minimum, 1.5 mm² or 16 AWG Lines, ferrule terminals, PE, M8 ring terminal Lines, ferrule terminals, PE, M4 ring terminal 22.0-33.0 mm 5.0-11.0 mm If your facilities do not provide the required AC 400VAC line-to-line voltage additional transformer equipment may be needed. Additional electrical configuration for the jumbo roll units Each jumbo unit requires an independent power line, complaint with the following specifications: Three-phase specifications: Number of power wires Input voltage (line-to-line) Input frequency Power consumption (typical) Maximum load current (per phase) Jumbo unit 4 (L1/L2/L3/PE) 400 V 50/60 Hz 2.5 kW 6 A Branch circuit breaker specifications Three-phase 3 poles, 10 A per unit AC three-phase power cable specifications Configuration Jumbo input/output units 4 (L1/L2/L3/PE) 10 Chapter 2 Site preparation ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

Specifications (continued)
Two-phase line
Single-phase control
Input voltage (line-to-line)
240 V
100–240 V
Input frequency
50/60 Hz
50/60 Hz
Power consumption (typical)
9–11 kW
0.5 kW
Maximum load current (per phase)
72 A
10 A
Branch circuit breaker specifications
Two-phase line
2 poles, 90 A
Two-phase control
2 poles, 15/16/20 A
AC power cable specifications
Two-phase line
Single-phase control
Configuration
3 wires, L1/L2/ PE
3 wires, L/N/PE
Wire
Strained Cu minimum, 4 AWG
Strained Cu minimum, 1.5 mm² or 16 AWG
Terminals
Lines, ferrule terminals, PE, M8 ring terminal
Lines, ferrule terminals, PE, M4 ring terminal
External diameter range
22.0–33.0 mm
5.0–11.0 mm
If your facilities do not provide the required AC 400VAC line-to-line voltage additional transformer equipment
may be needed.
Additional electrical configuration for the jumbo roll units
Each jumbo unit requires an independent power line, complaint with the following specifications:
Three-phase specifications:
Jumbo unit
Number of power wires
4 (L1/L2/L3/PE)
Input voltage (line-to-line)
400 V
Input frequency
50/60 Hz
Power consumption (typical)
2.5 kW
Maximum load current (per phase)
6 A
Branch circuit breaker specifications
Three-phase
3 poles, 10 A per unit
AC three-phase power cable specifications
Jumbo input/output units
Configuration
4 (L1/L2/L3/PE)
10
Chapter 2
Site preparation