Specifications, Standard Efficiency
View all HP ProDesk 600 G4 Micro manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 127 highlights
D Specifications Unit Value Chassis (in the desktop position) Height Width Depth 3.7 in 10.6 in 11.8 in 95 mm 270 mm 300 mm Approximate Weight 9.8 lb 4.43 kg Weight Supported (maximum distributed load in desktop position) 77 lb 35 kg Temperature Range Operating Nonoperating 50° to 95°F -22° to 140°F 10° to 35°C -30° to 60°C NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed. Relative Humidity (noncondensing) Operating Nonoperating (38.7°C max wet bulb) 10-90% 5-95% 10-90% 5-95% Maximum Altitude (unpressurized) Operating Nonoperating 16,404 ft 50,000 ft 5,000 m 15,240 m Power Supply Operating Voltage Range Rated Voltage Range1 Rated Line Frequency Operating Line Frequency 90-264 VAC 100-240 VAC 50-60 Hz 47-63 Hz Standard Efficiency High Efficiency 180 W / 250 W active PFC 82/85/82% efficient at 20/50/100% load (115V) Rated Input Current 250 W / 4 A 180 W / 2.3 A 1 This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark requirements for use in the countries of the European Union. The active power factor corrected power supply also has the added benefit of not requiring an input voltage range select switch. 119