HP ProLiant DL980 DL980 G7 User Installation Guide - Page 111

Specifications, Environmental Specifications

Page 111 highlights

Specifications Environmental Specifications Specification System inlet temperature Operating Non-operating Relative humidity (non-condensing) Operating Non-operating Altitude Operating Non-operating Acoustic noise Value - 10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). - 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. - 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Specifications 111

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

Specifications 111
Specifications
Environmental Specifications
Specification
Value
System inlet temperature
Operating
10° to 35°C (50° to 95°F) at sea level
with an altitude derating of 1.0°C per
every 305 m (1.8°F per every 1000
ft) above sea level to a maximum of
3050 m (10,000 ft), no direct
sustained sunlight.
Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be
limited by the type and number of
options
installed.
System performance may be reduced
if operating with a fan fault or above
30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F).
Maximum rate of change is 20°C/hr
(36°F/hr).
Relative humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh),
28°C (82.4°F) maximum wet bulb
temperature, non-condensing.
Non-operating
5 to 95% relative humidity (Rh),
38.7°C (101.7°F) maximum wet bulb
temperature, non-condensing.
Altitude
Operating
3050 m (10,000 ft). This value may
be limited by the type and number of
options installed. Maximum allowable
altitude change rate is 457 m/min
(1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum
allowable altitude change rate is 457
m/min (1500 ft/min).
Acoustic noise
Listed are the declared A-Weighted
sound power levels (LWAd) and
declared average bystander position
A-Weighted sound pressure levels
(LpAm) when the product is operating
in a 23°C ambient environment.