HP ProLiant MicroServer Gen8 HP ProLiant MicroServer Gen8 Maintenance and Serv - Page 80
Specifications, Environmental specifications, Server specifications, Power supply specifications
View all HP ProLiant MicroServer Gen8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 80 highlights
Specifications Environmental specifications Specification Value Temperature range* Operating Nonoperating 10°C to 35°C (50°F to 95°F) -30°C to 60°C (-22°F to 140°F) Relative humidity (noncondensing) Operating, maximum wet bulb temperature of 28°C (82.4°F) Nonoperating, maximum wet bulb temperature of 38.7°C (101.7°F) 10% to 90% 5% to 95% * All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Server specifications Specification Height Depth Width Weight, minimum (one drive, power supply, and processor installed) Weight, maximum (all drives, power supply, and processor installed) Server 23.25 cm (9.15 in) 24.50 cm (9.65 in) 23.00 cm (9.06 in) 7.40 kg (16.31 lb) 9.80 kg (21.60 lb) Power supply specifications The server supports one HP 150 W Integrated Power Supply. CAUTION: Check the system and power supply input ratings before powering up the server. HP 150 W Integrated Power Supply Specification Input requirements Value - Specifications 80