HP StorageWorks 8/40 Brocade Error Message Reference Guide v6.1.0 (53-1000600- - Page 102
BL-1010, Recommended, Action, systemVerification, diagPost, Severity, Message, Probable Cause
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
5 BL-1010 Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade. Severity CRITICAL BL-1010 Message , [BL-1010], ,, WARNING, , Blade in slot inconsistent with the hardware settings. Probable Cause Indicates that a failover occurred while some hardware changes were being made on the previously active control processor (CP) (such as changing the domain ID). Recommended No action is required. This blade has been reinitialized. Because reinitializing a blade is a disruptive Action operation and can stop I/O traffic, you might have to stop and restart the traffic during this process. Severity WARNING BL-1011 Message , [BL-1011], , FFDC, CRITICAL, , Busy with emb-port int. for chip in minis on blade , chip int. is disabled. interrupt status=0x. Probable Cause Indicates that too many interrupts in the embedded port caused the specified chip to be disabled. The probable cause is too many abnormal frames; the chip is disabled to prevent the control processor (CP) from becoming too busy. Recommended Action Make sure to capture the console output during this process. Check for a faulty cable, small form-factor pluggable (SFP), or device attached to the specified port. Run the systemVerification command to verify that the blade or switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace the blade or the nonbladed switch. Severity CRITICAL 50 Fabric OS Message Reference 53-1000600-02