54 PDM-1004 PDM-1004 Message , [PDM-1004], ,, WARNING, , PDM memory shortage. Probable Cause Indicates that the parity data manager (PDM) process ran out of memory. Recommended Action Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1005 Message , [PDM-1005], ,, WARNING, , FSS register failed. Probable Cause Indicates that the parity data manager (PDM) failed to register with the Fabos synchronization service (FSS). Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1006 Message , [PDM-1006], ,, WARNING, , Too many files in sync.conf. Probable Cause Indicates that the configuration file sync.conf contains too many entries. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1007 Message Probable Cause , [PDM-1007], ,, WARNING, , File not created: errno= . Indicates that the parity data manager (PDM) process failed to create the specified file. 332 Fabric OS Message Reference 53-1000600-02