SYSM System Messages, SYSM-1001
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 497 highlights
Chapter SYSM System Messages 72 SYSM-1001 Message , [SYSM-1001], , FFDC, CRITICAL, , No memory. Probable Cause Indicates that the switch has run out of system memory. Recommended Action Run the memShow command to view the switch memory usage. Reboot or power cycle the switch. Run supportFtp as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message , [SYSM-1002], ,, INFO, , , Switch: Probable Cause Indicates that a user has executed either the switchShutdown or switchReboot command. All services are brought down for a logical switch. Recommended Action No action is required if the switchShutdown or switchReboot command was executed intentionally. If the switchShutdown command was run, you must run the switchStart command to restart traffic on the logical switch. Severity INFO SYSM-1003 Message , [SYSM-1003], ,, INFO, , , Switch: Probable Cause Indicates that the user executed the switchStart or switchReboot command. This indicates that all services are brought back up after a temporary shutdown of that logical switch. Recommended Action No action is required if the switchStart command was executed intentionally. Because reinitializing a switch is a disruptive operation and can stop I/O traffic, you might have to stop and restart the traffic during this process. Severity INFO Fabric OS Message Reference 445 53-1000600-02