HP StorageWorks 8/40 Brocade Error Message Reference Guide v6.1.0 (53-1000600- - Page 570
SULB-1035, Recommended, Action, firmwareDownloadStatus, Severity, Message, Probable Cause, reboot
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 570 highlights
8 SULB-1035 Recommended Action Reboot the switch. This will cause the internal image to be relocated again. Use the firmwareDownloadStatus to monitor the progress. If the problem persists, contact your switch service provider. Severity ERROR SULB-1035 Message AUDIT, , [SULB-1035], ERROR, FIRMWARE, , , , An error has occurred relocation of the internal image. Probable Cause Indicates that an error has occurred during the relocation of the internal image. The error may be caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or persistent storage hardware failure. Recommended Reset the switch. This will cause the internal image to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, , , , HCL failed. Reboot the switch manually using the reboot command. However, it will disrupt the FC traffic. Probable Cause Many reasons can cause HCL to fail, such as domain not confirmed. Recommended Run the reboot command to reboot the switch manually. Action Severity Error 518 Fabric OS Message Reference 53-1000600-02