HP Tc2120 HP Server Ultra 3 SCSI Host Bus Adapter Installation and Configurati - Page 53
Bit Mask Options
UPC - 808736945332
View all HP Tc2120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
Chapter 5 Novell NetWare Installation Table 5-1. adpt160m.ham Command Line Options Option multlun_targets= slot= verbose= Values 0-FFFF Default FFFF 0-xxxx2 0 yes, no no Description A bit mask to enable LUNs on selected targets. By default, LUNs on all targets are enabled. This bit mask is entered in hex (see "Bit Mask Options" on page 47). Defines a physical slot number for the host adapter. If 0 is specified, or if this option is not specified, then the driver loads for all Ultra3 host adapters. Displays host adapter configuration information at load time. 1Many multiple-LUN and removable-media devices are changers or magazines. Some of these are only supported by the driver through an ASPI driver provided by the hardware vendor. 2The values can vary and are dependent on the system configuration. Bit Mask Options Use the example below as an aid for calculating bit mask option hex values. Each SCSI device is enabled by a 1 in its corresponding bit position. The table that follows the figure lists the binary-to-hex conversions. Using this example, if you want to enable scanning for LUNs 0, 2, and 6 on all targets, then use the command line option of lun_enable=0045. 47