HP Workstation x4000 hp workstation x4000 - Getting Started Guide - Windows (A - Page 42
HP x4000 Technical Characteristics,
![]() |
View all HP Workstation x4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Troubleshooting HP x4000 Technical Characteristics NOTE Table 2-2 HP x4000 Technical Characteristics Operating temperature and humidity ranges may vary depending on the mass storage devices installed. High humidity levels can cause improper operation of disk drives. Low humidity ranges can aggravate static electricity problems and cause excessive wear of the disk surface. When you turn off your workstation with the power button on the front panel, the power consumption falls below 10W, but is not zero. To reach zero power consumption when the computer is off, either unplug the workstation from the power outlet or use a power strip with a switch. x4000 Technical Characteristics Weight Dimensions Footprint Power Supply Input voltage Input frequency Typical input power Max avg input power Maximum output power Storage Humidity Minimum configuration: 40.20 lb. (18.24 kg) Maximum configuration: 45.40 lb. (20.60 kg) Width: 8.22 in. (20.90 cm) Height: 19.02 in. (48.30 cm) Depth: 18.62 in. (47.3cm) 153.06 in. (988.57 cm) 90 - 250 VAC 50/60 Hz 365 W 500 W 465 W 90% (relative, non-condensing) Operating Humidity 15 to 80% (relative, non-condensing) Storage Temperature Operating Temperature Altitude -40o C (-40o F) to 70o C (158o F) 5o C (41o F) to 35o C (95o F) Operating: 0 to 10,000 ft. (3100 m) Non-operating: 0 to 15,000 ft. (4500 m) 42 Chapter 2
![](/manual_guide/products/hewlettpackard-workstation-x4000-hp-workstation-x4000-getting-started-guide-windows-a805890001-e0502-2a90ae3/42.png)