HP XP20000/XP24000 HP StorageWorks XP24000/XP20000 Audit Log Reference Guide ( - Page 173
Restore Operation, Normal end, Seq.=x, Detailed Information, Example 1 restoring a PCB, Maintenance]
View all HP XP20000/XP24000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 173 highlights
Normal end The operation has ended normally. Seq.=xxxxxx Sequence number of log information (0000000000 to 4294967295) Detailed Information Detailed information displays for this operation, as shown in Table 207 (page 173). Table 207 Replace Operation Item Parts name SFP Num. of SFPs PCB Failed Description The name of the parts (EPOSW, PCICON, PCIADP, DKCPANEL, PSxx, PS-xx, BATTERY-xx, ACBOX-x, FAN-xx, TH-xx, SSVP/MN, SVP, HDDFANxx-x, BATTERY-Uxxx, BATREG-x, FUSE-xxx, ACBOX-Uxxx, DKUPS-xxx, SVRxxx-x, SVRxxx-Ex, EXTADP, BATTERY-SBx, SBADP, or LEDPNLxx-x) specified to be replaced. The port where SFPs are inserted. The number of inserted SFPs. The mounting location of the PCB, CHA, DKA, cache memory, CM, SM, cache switch, MIX or BASE) to be replaced. When replacing multiple PCBs and some of the PCBs to be replaced had failures, the mounting locations of the failed PCBs are indicated. In such case, Warning is output as the result of the process. NOTE: This information is not output when there are no failed PCBs. Num. of PCBs PDEV Copy The number of PCBs to be replaced. The mounting location of the PDEVs to be replaced. The status of copy process when replacing PDEVs. This information is output only when replacing PDEVs. Restore Data: Data recovery from spare disk, Correction Copy: correction copy Diagnosis Micro Program Num. of PDEV FSW Num. of FSWs Diagnosis is output only when INLINE skip is selected when replacing PDEVs. This information is output only when replacing PDEVs. Micro Program is output only when microcode update is skipped when replacing PDEVs. This information is output only when replacing PDEVs. The number of PDEVs to be replaced. This information is output only when easy replacing PDEVs. The mounting location of fibre switches to be replaced. The number of fibre switches to be replaced. Restore Operation Example 1 (restoring a PCB) user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Maintenance],Restore,,Normal end,,,Seq.=xxxxx +PCB=[CHA-1P],Num. of PCBs=1 +PDEV=HDD00-01 Example 2 (restoring an LDEV) user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Maintenance],Restore,,Normal end,,,Seq.=xxxxx +PG=[1-1],Num. of PGs=1 +PG=[E1-1],Num. of PGs=1 (for an external volume) +PG=[V1-1],Num. of PGs=1 (for a virtual volume) +PG=[X1-1],Num. of PGs=1 (for a Dynamic Provisioning volume) +LDEV=[0x00:0x03:0x2f],Num. of LDEVs=1 [Maintenance] Maintenance function Restore Operation 173