HP Xw6200 Adaptec SCSI RAID 2120S: Software Reference Guide - Page 283
following example, You may want to use
UPC - 882780333536
View all HP Xw6200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 283 highlights
enclosure Commands The following example sets the monitor reporting interval for enclosure management devices 0 and 1 to 20 seconds: AAC0>enclosure set interval 20 Executing: enclosure set interval 20 You may want to use the enclosure show status command again to see the change in the power supply's status, as in the following example: Enclosure UpTime D:H:M PowerCycle Interval Door Alarm 0 0:00:00 0 20 UNLOCKED OFF . . . Enclosure UpTime D:H:M PowerCycle Interval Door Alarm 1 0:00:00 0 20 UNLOCKED OFF Related Information enclosure commands: ■ enclosure list (page 11-7) ■ enclosure show status (page 11-37) 11-19
11-19
enclosure Commands
The following example sets the monitor reporting interval for
enclosure management devices
0
and
1
to
20
seconds:
AAC0>enclosure set interval 20
Executing: enclosure set interval 20
You may want to use the
enclosure show status
command
again to see the change in the power supply’s status, as in the
following example:
Enclosure UpTime D:H:M
PowerCycle Interval Door
Alarm
--------- -------------- ---------- -------- -------- -------
0
0:00:00
0
20
UNLOCKED OFF
.
.
.
Enclosure UpTime D:H:M
PowerCycle Interval Door
Alarm
--------- -------------- ---------- -------- -------- -------
1
0:00:00
0
20
UNLOCKED OFF
Related Information
enclosure
commands:
■
enclosure list
(
page 11-7
)
■
enclosure show status
(