HP Xw6200 Adaptec SCSI RAID 2120S: Software Reference Guide - Page 36
Letter, Action, Integer, Value in decimal, with or without quotation marks. If
![]() |
UPC - 882780333536
View all HP Xw6200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Adaptec SCSI RAID Software Reference Guide Table 3-1. Letters and Multiplicative Values Letter K (kilobytes) M (megabytes) G (gigabytes) T (terabytes) Action multiplies by 1024 multiplies by 1024*1024 multiplies by 1024*1024*1024 multiplies by 1024*1024*1024*1024 You cannot use decimal points. To specify 1.5 GB, for example, you must use (3G/2). Note: All suffixes are case-insensitive! That is, you can use upper or lower-case characters. For example you can specify 10 M or 10 m. Table 3-2 lists examples of valid integers and their corresponding values: Table 3-2. Integers and Values (in Decimal) Integer 219 3*4 (5+3*24) (5+(3*24)) 0x123 (12+52h+1010z) 100M 2G Value (in decimal) 219 12 192 77 291 104 104,857,600 2,147,483,648 string You can specify a text string with or without quotation marks. If spaces are needed, however, the string must be specified with quotation marks; otherwise, the CLI interprets spaces as delimiters. A string can use either double quotes or single quotes but must start and end with the same type of quotes. Also, within a quoted string, 3-6