Hikvision DS-7316HQHI-SH User Manual - Page 121

Manually Rebuilding Array

Page 121 highlights

Figure 138 Firmware Interface 2. Check the Auto-rebuild box to enable auto-rebuild. Since the hot spare disk is configured and Auto-rebuild function is enabled. The hot spare disk will be automatically used for array rebuilding when the status of the array is Disk Loss. You can check the rebuild status by going to Menu > System Configuration > RAID. 1. Select Array tab to view the array rebuilding status. Figure 139 Array Interface 2. Select Virtual Disk tab to view the virtual disk rebuilding status. Figure 140 Virtual Disk Interface Note: If there is no hot spare disk after rebuilding, it is recommended to install a HDD into the device and set is as a hot spare disk to ensure the high security and reliability of the array. Manually Rebuilding Array If you do not enable the Auto-rebuild in Firmware interface or the hot spare disk has not been configured, you can rebuild the array manually to restore the array when the virtual disk is in Degraded status. To manually rebuilding array: 1. Enter the Array interface by going to Menu > System Configuration > RAID > Array tab. 2. Click to pop up the Rebuild Array box. 120

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143

120
Figure 138
Firmware Interface
2.
Check the Auto-rebuild box to enable auto-rebuild.
Since the hot spare disk is configured and Auto-rebuild function is enabled. The hot spare disk
will be automatically used for array rebuilding when the status of the array is Disk Loss. You can
check the rebuild status by going to Menu > System Configuration > RAID.
1.
Select Array tab to view the array rebuilding status.
Figure 139
Array Interface
2.
Select Virtual Disk tab to view the virtual disk rebuilding status.
Figure 140
Virtual Disk Interface
Note:
If there is no hot spare disk after rebuilding, it is recommended to install a HDD into the device
and set is as a hot spare disk to ensure the high security and reliability of the array.
Manually Rebuilding Array
If you do not enable the Auto-rebuild in Firmware interface or the hot spare disk has not been
configured, you can rebuild the array manually to restore the array when the virtual disk is in
Degraded status. To manually rebuilding array:
1.
Enter the Array interface by going to Menu > System Configuration > RAID > Array tab.
2.
Click
to pop up the Rebuild Array box.